Section 5: Maintenance
Maintenance and Repairs
2018 Insta-Berm (Frame) Operations Manual
(Version D)
23
We Engineer Solutions
Section 5: Maintenance
Maintenance and Repairs
Spill Clean-Up
Chemical resistance data is based on an exposure limit of 28 days duration at room temperature. The liner
may be over-lined with disposable thin polyethylene sheeting for rapid clean up of spills.
Removing Water and Foreign Materials
If the water has any chemicals floating on the surface or suspended in the water, a filter system should be
used to eliminate these chemicals before allowing the water to return to the environment. SEI Industries
recommends using SEI’s RainDrain system for removing hydro-carbons. For non hydro-carbon chemicals,
contact the local authorities to determine how to safely dispose of the chemicals.
To facilitate the pumping of water from inside the berm, each berm should be equipped with a manually
operated pump. The pump should be located at the lowest point in the berm. An automatic pump should
not be used as it would pump out any spillage in the berm.
If the Insta-Berm is installed on a grade, the liner can be un-hooked from the top pipe on the downhill side
to allow the water to drain. Re-install the liner on the top pipe after draining the water. Do not leave the
berm unattended while one side is lowered to facilitate draining. SEI Industries can automate this process
with the RainDrain system. See this manual for more information.
Caution
The Insta-Berm system is for temporary secondary containment. Neutralize or transfer spills
collected within the liner to permanent holding containers promptly.
Caution
SEI Industries will not be liable for any loss of stored liquids or related damage. To maximize spill
retention, inspect the Insta-Berm frequently and remove rain water, snow or dirt promptly from