![Segger Flasher ATE Скачать руководство пользователя страница 72](http://html1.mh-extra.com/html/segger/flasher-ate/flasher-ate_user-manual_1233803072.webp)
72
CHAPTER 8
ASCII command interface
#POWERON
This command can be used to turn on the target power without any erase, program or
verify action.
Command structure:
#POWERON [module1][,module2][,module3] [Power Source],[Discharge]
The power on command expects the following parameters:
Parameter
Meaning
Power Source
0 = internal power,
1 = VTgt
Discharge
1 = discharge target when turning the power off (needs to be set
with the power on command),
0 = no discharge
Example sequence:
Command send to
the Flasher ATE
Reply on the main channel
(RS232 or telnet connection)
Reply on the target
channel (telnet connection
to flash module)
#POWERON 1,2,3 1,0
#ACK
#DONE
The connection of the power supply is described in the chapter
Target power supply
on
page 89.
Flasher ATE User Guide (UM08035)
© 2017-2018 SEGGER Microcontroller GmbH