48
CHAPTER 4
Limiting the number of programming cycles
4.2 Limiting the number of programming cycles
The Flasher ATE provides a mechanism to limit the number of programming cycles that can
be performed in stand-alone mode with the configuration that is stored on the Flasher ATE.
To make use of this feature, a file called
Cntdown.txt
needs to be placed on the Flasher
ATE module folder. This file simply contains a decimal number (32-bit unsigned integer)
that describes how many programming cycles can be performed with the current setup.
Note
The number in the
Cntdown.txt
is only updated on a successful programming cycle.
Programming cycles that failed do not affect the
Cntdown.txt
.
4.2.1 Changed fail/error LED indicator behavior
In case a
Cntdown.txt
is found at boot time, the fail/error LED of Flasher behaves different
from normal. If the number of programming cycles left is 10 or below, the following will
happen:
• The red error/fail LED will be lit for 1 second
• After this, it will blink/toggle x times @ 5 Hz, indicating the number of programming
cycles left. (blinking 5 times for 5 cycles left, …)
Flasher ATE User Guide (UM08035)
© 2017-2018 SEGGER Microcontroller GmbH
Содержание Flasher ATE
Страница 4: ...4 Flasher ATE User Guide UM08035 2017 2018 SEGGER Microcontroller GmbH...
Страница 6: ...6 Flasher ATE User Guide UM08035 2017 2018 SEGGER Microcontroller GmbH...
Страница 20: ...20 CHAPTER 2 Setting up the IP interface Flasher ATE User Guide UM08035 2017 2018 SEGGER Microcontroller GmbH...
Страница 22: ...22 CHAPTER 2 Operating modes Flasher ATE User Guide UM08035 2017 2018 SEGGER Microcontroller GmbH...
Страница 60: ...60 CHAPTER 8 ASCII command interface Flasher ATE User Guide UM08035 2017 2018 SEGGER Microcontroller GmbH...