CHAPTER 2
LED status indicators
2.4 LED status indicators
The Flasher ATE uses different LEDs, see the following tables.
2.4.1 Mainboard LED indicators
#
Status of mainboard LEDs
Meaning
USB
GREEN
high frequency blinking
(~ 10Hz)
The mainboard is waiting for USB enumeration. As
soon as USB has been enumerated, the green LED
stops flashing and is switched to constant green.
1
USB GREEN
constant
The mainboard has completed USB enumeration or
no USB connection present.
2
USB RED
constant
The mainboard is in bootloader mode.
3
READY/BUSY
GREEN
No operation, the Flasher is ready.
4
READY/BUSY
RED
Flashing operation in progress on at least one mod-
ule.
5
PASS/ERROR
GREEN
The last operation was successful on all modules.
6
PASS/ERROR
RED
The last operation has failed on at least one mod-
ule.
7
VMAIN
GREEN
VMAIN is used as module power supply.
8
VUSB
GREEN
VUSB is used as module power supply
1
.
1
The VUSB LED does not work on mainboards hardware version 1.0. This has no influence
on functionality.
2.4.2 Module LED indicators
LED
Status
Meaning
STATUS GREEN
short flashing
The module waits for a start trigger.
1
STATUS
GREEN
slow blinking
Flashing operation in progress:
• Erasing (blinking at 6.25 Hz)
• Programming (blinking at 1.67 Hz)
• Verifying (blinking at 5 Hz)
2
STATUS
RED
constant
a) The module is in bootloader mode.
b) The last operation has failed.
3
5V
GREEN
Internal power supply for 5V is working.
4
3.3V
GREEN
Internal power supply for 3.3V is working.
5
VCC5V
GREEN
Target power is enabled via internal supply.
6
VTGT
GREEN
Target power is enabled via external supply.
Flasher ATE User Guide (UM08035)
© 2017-2018 SEGGER Microcontroller GmbH
Содержание Flasher ATE
Страница 4: ...4 Flasher ATE User Guide UM08035 2017 2018 SEGGER Microcontroller GmbH...
Страница 6: ...6 Flasher ATE User Guide UM08035 2017 2018 SEGGER Microcontroller GmbH...
Страница 20: ...20 CHAPTER 2 Setting up the IP interface Flasher ATE User Guide UM08035 2017 2018 SEGGER Microcontroller GmbH...
Страница 22: ...22 CHAPTER 2 Operating modes Flasher ATE User Guide UM08035 2017 2018 SEGGER Microcontroller GmbH...
Страница 60: ...60 CHAPTER 8 ASCII command interface Flasher ATE User Guide UM08035 2017 2018 SEGGER Microcontroller GmbH...