98
PROBLEMS CAUSE
COUNTERMEASURES
Sound volume adjustment is
not appropriate.
Adjust sound volume (see Sec. 5).
No sound is emitted.
Control Unit sighting is not
satisfactory.
Board and amplifier
malfunctioning
Perform the sound test and confirm (see
Sec. 5).
Sights are not aligned due to
changes in the surrounding
environment.
Perform sighting adjustment in the test
mode (see Sec. 5).
LED board malfunctioning.
Check to ensure that the LED lights up.
If it does not light up, replace (see next
page).
Sensor unit malfunctioning
Replace the sensor unit (see Sec. 6).
LED board and LED board
cover are contaminated.
Wipe off soiled surfaces (see next
page).
During game play, the
control unit is not operable
for shooting.
The operation of the
ACTION button and SHOT
SELECTOR are
unsatisfactory.
The gun controller does not
vibrate.
The FL does not light up.
The lamp does not light up.
Fuse on the connector board
has blown due to a momentary
electrical overload.
Fix the source of the overload, then
replace the fuse. <Fuse: 250V 200mA,
514-5086-200> (see Sec. 10)
Microswitch malfunctioning
Check that the switches turn off and on
using test mode. Replace the switch if it
does not operate (see Sec. 6).
LED board malfunctioning
If does not light up, replace (see next
page).
Sensor board malfunctioning
Replace the sensor board.
Cannot read properly from
an IC card or the IC card is
not detected.
No sound is emitted.
Control Unit sighting is not
satisfactory.
Fuse on the connector board
has blown due to a momentary
electrical overload.
Fix the source of the overload, then
replace the fuse. <Fuse: 250V 200mA,
514-5086-200> (see Sec. 10)
During game play, the
control unit is not operable
for shooting.
Microswitch malfunctioning
Check that the switches turn off and on
using test mode. Replace the switch if it
does not operate (see Sec. 6).
Solenoid is broken.
Replace the solenoid (see Sec. 6).
The operation of the
ACTION button and SHOT
SELECTOR are
unsatisfactory.
The gun controller does not
vibrate.
Fuse on the connector board
has blown due to a momentary
electrical overload.
Fix the source of the overload, then
replace the fuse. <Fuse: 250V 200mA,
514-5086-200> (see Sec. 10)
The FL does not light up.
The FL has burnt out.
Replace the fluorescent light.
The lamp does not light up. Lamp has burnt out.
Replace the lamp.
Using an unsupported card
Card reader settings are
incorrect.
Correct the settings using Test
mode(see Sec. 5).
Check the operation using Test mode.
Check the connector connection.
Connector is not connected
properly.
Clean the IC card unit (see Sec. 7).
IC card unit is dirty.
Contact your supplier
Cannot read properly from
an IC card or the IC card is
not detected.
No sound is emitted.
Control Unit sighting is not
satisfactory.
During game play, the
control unit is not operable
for shooting.
IC card unit is broken.
Clear out the foreigner matter (see Sec.
7).
The operation of the
ACTION button and SHOT
SELECTOR are
unsatisfactory.
Foreign matter has entered the
reader/writer.
Adjust sound volume (see Sec. 7).
Содержание Ghost Squad Deluxe
Страница 9: ...8...
Страница 14: ...13 4 Attach the assembled billboard pop using the 2 truss screws...
Страница 82: ...81 7 Undo the 2 screws and remove the sensor bracket 8 Undo the 4 screws and remove the RW guide upper...
Страница 108: ...107 11 DESIGN RELATED PARTS...
Страница 109: ...108 12 PARTS LIST 12 1 ASSY PTV CTF 0500 UK...
Страница 111: ...110 12 2 ASSY BILLBOARD DX CTF 0550UK...
Страница 113: ...112 12 3 ASSY FRONT PANEL CTF 0600UK...
Страница 115: ...114 12 4 ASSY PTV BASE CTF 0650UK...
Страница 117: ...116 12 5 ASSY SUB PTV BASE CTF 0660UK...
Страница 120: ...119 12 7 ASSY CABINET DX CTF 1000...
Страница 122: ...121 12 8 13 7 ASSY SUB CABI DX CTF 1100UK...
Страница 126: ...125 12 9 ASSY LATCH CTF 1170UK...
Страница 128: ...127 12 10 ASSY RW UNIT CTF 1150...
Страница 130: ...129 12 11 ASSY CONTROLLER HOLDER L CTF 1300UK Note Fastening torque for item 201 is 1 4Nm 14Kgf cm...
Страница 132: ...131 12 12 ASSY CONTROLLER HOLDER R CTF 1320UK Note Fastening torque for item 201 is 1 4Nm 14Kgf cm...
Страница 134: ...133 12 13 ASSY HOLDER LIGHT CTF 1340UK...
Страница 136: ...135 12 14 ASSY CONTROL PANEL CTF 2000UK...
Страница 138: ...137 12 15 CONTROL UNIT CTF 2100...
Страница 140: ...139 12 16 SENSOR UNIT JPT 2030...
Страница 142: ...141 12 17 ASSY MAIN BD CTF 4000UK...
Страница 144: ...143 12 18 ASSY ELEC CTF 4100UK...
Страница 147: ...LOCATE A3 SCHEMATIC DRAWING 1 HERE...
Страница 148: ...LOCATE A3 SCHEMATIC DRAWING 2 HERE...
Страница 149: ...LOCATE A3 SCHEMATIC DRAWING 3 HERE...