10.3. ERROR CODES
•
If an error code is displayed, have a Location's Maintenance Man or
Serviceman resolve it. If someone without specialized or technical
knowledge attempts to rectify the problem, electric shock, short circuits or
fire may result. If there is no store maintenance person or technician
available, turn the power OFF immediately, and contact your retailer or the
office listed in this manual.
•
If problems other than those noted in this manual occur, or the
countermeasures suggested result in no improvement, do not try to rectify
the problem by other means. Turn the power OFF immediately, and contact
your retailer or the office listed in this manual. Careless countermeasures
can result in unexpected accidents.
•
If error No. 20 is generated, the power must be turned OFF and ON again in
order to clear it.
•
When requesting replacement or repair of the Game Board or Media Board,
put the board in the special purpose packing box specified in this manual for
transportation.
Chihiro displays error messages on the screen to indicate various problems.
If an error message is displayed, the game cannot be started. In this case, refer to the following section on
causes and countermeasures.
In the text for this product below, "Media Board" and "DIMM" are one and the same.
Error 02
[DISPLAY] Error
02
Main board malfunctioning.
[CAUSE]
MAIN BOARD is inoperative.
[COUNTERMEASURES]
Verify that the MAIN BOARD is connected properly.
Error 03
[DISPLAY] Error
03
Bad serial number on main board.
[CAUSE]
Unable to read MAIN BOARD serial ID.
[COUNTERMEASURES]
Disconnect the MEDIA BOARD from the MAIN BOARD and send
the MAIN BOARD for repair.
Error 04
[DISPLAY] Error
04
Bad serial number on media board.
[CAUSE]
Unable to read MEDIA BOARD serial ID.
[COUNTERMEASURES]
With the MEDIA BOARD still attached to the MAIN BOARD, send
the Chihiro for repair.
Error 05
[DISPLAY] Error
05
This game is not acceptable by main board.
[CAUSE] The
game
is
a foreign edition.
[COUNTERMEASURES]
Use the domestic version of the game.
Содержание Ghost Squad Deluxe
Страница 9: ...8...
Страница 14: ...13 4 Attach the assembled billboard pop using the 2 truss screws...
Страница 82: ...81 7 Undo the 2 screws and remove the sensor bracket 8 Undo the 4 screws and remove the RW guide upper...
Страница 108: ...107 11 DESIGN RELATED PARTS...
Страница 109: ...108 12 PARTS LIST 12 1 ASSY PTV CTF 0500 UK...
Страница 111: ...110 12 2 ASSY BILLBOARD DX CTF 0550UK...
Страница 113: ...112 12 3 ASSY FRONT PANEL CTF 0600UK...
Страница 115: ...114 12 4 ASSY PTV BASE CTF 0650UK...
Страница 117: ...116 12 5 ASSY SUB PTV BASE CTF 0660UK...
Страница 120: ...119 12 7 ASSY CABINET DX CTF 1000...
Страница 122: ...121 12 8 13 7 ASSY SUB CABI DX CTF 1100UK...
Страница 126: ...125 12 9 ASSY LATCH CTF 1170UK...
Страница 128: ...127 12 10 ASSY RW UNIT CTF 1150...
Страница 130: ...129 12 11 ASSY CONTROLLER HOLDER L CTF 1300UK Note Fastening torque for item 201 is 1 4Nm 14Kgf cm...
Страница 132: ...131 12 12 ASSY CONTROLLER HOLDER R CTF 1320UK Note Fastening torque for item 201 is 1 4Nm 14Kgf cm...
Страница 134: ...133 12 13 ASSY HOLDER LIGHT CTF 1340UK...
Страница 136: ...135 12 14 ASSY CONTROL PANEL CTF 2000UK...
Страница 138: ...137 12 15 CONTROL UNIT CTF 2100...
Страница 140: ...139 12 16 SENSOR UNIT JPT 2030...
Страница 142: ...141 12 17 ASSY MAIN BD CTF 4000UK...
Страница 144: ...143 12 18 ASSY ELEC CTF 4100UK...
Страница 147: ...LOCATE A3 SCHEMATIC DRAWING 1 HERE...
Страница 148: ...LOCATE A3 SCHEMATIC DRAWING 2 HERE...
Страница 149: ...LOCATE A3 SCHEMATIC DRAWING 3 HERE...