BREEZAIR EXVQ EVAPORATIVE COOLER INSTALLATION MANUAL
|
9
Once the solenoid valve and its cable has been fitted, place the
cover over the assembly. Make sure the solenoid valve cable is
retained in the groove in the cooler pan (reservoir). Secure the
cover by tightening the flexible hose assembly nut (C).
Important!
Make sure the cable cannot lay in the water at any
stage. Connect the electrical leads to the solenoid.
The electrical cable leads may be connected to the solenoid
either way around.
Taps or shutoff valves used must not be of the non - return type.
Water drained from the cooler must be carried away to a
suitable discharge point in accordance with local regulations.
A
C
D
E
B
ILL746-E
A Drain Valve
B O-Ring
C Nut
D Drain Adaptor
E Lock Nut
INSTALLING THE DRAIN VALVE
Water drained from the cooler must be carried away to a
suitable discharge point in accordance with local regulations.
Important!
Never drain water from the cooler directly on to the
roof.
Make sure the “O”-ring (B) is fitted before placing the drain
valve into the hole.
Screw the nut (C) up tightly by hand underneath to locate the
drain valve.
Locate the drain adaptor (D) up against the bottom of the drain
valve thread and secure with the second, larger nut (E).
Make sure that you use the correct drain adaptor. Make sure
the drain water discharge flows freely away from the cooler.
Important!
Do not over-tighten plastic fittings.
Connect the drain valve cable to the cooler electronics box.
DRAIN VALVE ASSEMBLY
Assemble the drain valve as shown:
INSTALLATION
FITTING THE SOLENOID COVER
Refer to the installation manual provided with the wall controller
for instructions on installing the controller. Coolers are supplied
with a 66’ (20m) control cable. Longer cable lengths are
available from Seeley.
Important!
The maximum cable length allowed from the
MagIQtouch controller to the first cooler is 82’ (25m). For any
additional coolers added into the system with a link module the
maximum allowed length is 131’ (40m). Therefore, failure of the
product or components to operate correctly due to modification
to supplied cables, or the use of non-approved cables will NOT
be accepted under the Manufacturer’s Warranty.
We have this cable available through our sales order office and
spare parts outlets in the following lengths:
CONNECTING THE MAGIQTOUCH CONTROLLER
ILL3387-A
ILL3387-A
Once the controller is connected, power up the cooler using the
ON/OFF switch on the cooler electronics box.
Part No. Length Details
833880
66’
MagIQtouch Controller Cable (No Ferrite)
862873
5’
MagIQtouch Controller Cable (No Ferrite)
861265
10’
MagIQtouch Controller Cable (No Ferrite)
864396
98’
MagIQtouch Controller Cable (With Ferrite)
864402
131’
MagIQtouch Controller Cable (With Ferrite)
IMPORTANT NOTES:
•
The cooler electronics box is a non-serviceable part.
Do not open or attempt to repair any components.
•
The cooler electronics box cover will only open and close with
the ON / OFF switch in the “OFF” position. Do not try to force
the cover open with the switch in the “ON” position.
• Always turn “OFF” mains power to the cooler before checking
connections or touching wiring and components connected to
the cooler electronics box.
• Take care to position the cables into the cover slots when
closing, so that they do not become caught or pinched.
•
The cooler electronics box is fitted with a 12A re-settable
circuit breaker. To reset the circuit breaker isolate power from
the cooler, and push the manual reset toggle switch located
on the base of the cooler electronics box.