GAS CONNECTION
If bottled gas is being used to supply the ducted gas heater,
then we strongly recommend that an UPSO regulator be
installed in the gas line upstream of the unit. Damage can
occur to the ducted gas heating unit if it is operated when the
gas supply has run out or is running low. A correctly installed
UPSO regulator in the gas line will protect the ducted gas
heating unit from such damage (and may also protect other
gas appliances in the house), because it will turn off the gas
supply if the gas runs out or runs too low.”
All gas supply piping must be installed by a licensed gas fitter in
accordance with Standard AS/NZS 5601 Gas Installations.
Gas connection point: All models - 3/4" BSP female flare nut.
Gas supply piping must be sized to ensure a minimum gas
pressure of 1.13 kPa for natural gas appliances or 2.75 kPa
for propane appliances at the inlet to the heater with the heater
and all other gas appliances operating at maximum gas rate.
Detailed pipe sizing information is contained in Standard AS/NZS
5601 Gas Installations.
T
he maximum gas rate for the heater is located on the
specification label on the underside of the heater lid.
An AGA approved gas cock/manual shut-off valve must be fitted
in the gas supply line adjacent to the heater (outside the heater
cabinet) to enable isolation of the heater for maintenance and/or
servicing.
Ensure that all air is purged out of the gas line.
Ensure that there are no gas leaks.
Gas Connection
All Models
7
TQ3, TQ4, TQ5, TQM5, TQM6, TQS3, TQS4, TQS5, TQS6
ELECTRICAL CONNECTION
Electrical wiring & fittings must be installed by a licensed
Electrician.
S
eeley International recommends that all Braemar gas ducted
heaters are wired with a dedicated circuit from the distribution
board with a separate circuit breaker.
Wiring must be installed in accordance with the relevant
electrical standards & regulations.
The electrical supply must be 240V 50Hz
.
A conventional 10A 3-pin 240V GPO must be fitted adjacent to the
heater.
Ensure that the polarity of the power supply is correct.
If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified persons in
order to avoid a hazard.
UNDER NO CIRCUMSTANCES SHOULD DOUBLE ADAPTERS,
POWER BOARDS OR EXTENSION LEADS BE USED.
Neutral
Active
Earth
IMPORTANT
ENSURE THAT POLARITY OF
POWER SUPPLY IS CORRECT
MAGIQTOUCH CONTROLLER OR
MAGIQTOUCH AIR SENSOR LOCATION
MagIQtouch Controller
Refer to the installation manual provided with the MagIQtouch
Controller for mounting and installation instructions.
MagIQtouch Air Sensor
Refer to the installation manual provided with the MagIQtouch Air
Sensor for mounting and installation instructions.
The MagIQtouch Controller is required to obtain full functionality
with Braemar heater, including zoning (All heaters except TQ3
models) and evaporative or refrigerated cooler operation.
With the addition of multiple optional MagIQtouch Zone Control
kits and MagIQtouch Link Module kits, heaters can be used with
up to 10 controllers with each controller controlling its own
independent zone.
24V Manual Digital Controller
Refer to the installation manual provided with the 24V Manual
Controller for mounting and installation instructions.
All heaters can all be used with a standard 2-wire type
manual digital controller. Connect a low voltage 2-wire loom
between the Manual controller and "T STAT" on the ICS circuit
board. Note that with Braemar TQ, TQM, TQS series heaters
zoning, evaporative or add-on cooling operation and room
fan speed adjustment is not possible with these thermostats.
MAGIQTOUCH CONTROLLER CONNECTION
Connect one end of the MagIQtouch controller cable to terminal
labeled wall control on the ICS.