![SEELEY INTERNATIONAL Braemar Ecostar TQ3 Скачать руководство пользователя страница 17](http://html.mh-extra.com/html/seeley-international/braemar-ecostar-tq3/braemar-ecostar-tq3_installation-manual_1233143017.webp)
ADJUSTING HEATER SETTINGS
Within the SETTINGS menu of the MagIQtouch Controller is the
HEATER sub-heading. Here various settings of the heater can be
adjusted
ABOUT APPLIANCE
Displays information such as model number, serial number and
software version for heater connected to the MagIQtouch controller.
MIN / MAX SET TEMPERATURE
You can change the minimum and maximum temperature displayed
on your slider, depending on what temperature range you prefer
your system to work within.
NIGHT QUIET MODE
Restricts fan speed to a specified level during specified night period.
MAX SYSTEM FAN SPEED
Adjust system max fan speed (refer Adjusting Fan Speed section).
BUILDER LOCK / UNLOCK
Can be used to temporarily lock the heater by the installer. The
installer will need to unlock the heater at the appropriate time before
heater can be used.
TROUBLE SHOOTING & DIAGNOSTICS
If the heater fails to start, try the following:
No power.
Is green LED on ICS circuit board on?
Plug in heater supply lead
Turn on power
Turn on circuit breaker
No gas supply.
Min' supply pressure
1.13 kPa (NG)
Has gas meter been installed?
Turn gas on at gas meter
Controller not connected
Connect "manual/2-wire" thermostat to "MANUAL
T/STAT" terminals on ICS.
Connect MagIQtouch Controller to "WALL
CONTROL terminals on ICS.
No Controller communication.
Refer to System Setup section of this manual.
MagIQtouch Controller not calling for heat
Adjust set point above current room temperature.
Check LED's - HT LED (red) This LED indicates if the
controller is calling for heat or not. ON = Calling for
heat, OFF = Not calling for heat
Combustion fan does not start
Check that the fan is not blocked or jammed
No spark
Check flue cowl is installed correctly
Check wiring to pressure switch is not dislodged
Check that spark lead is connected
Spark but no ignition
Check gas valve on/off switch is set to ON
Check Gas tap is turned on
Room fan does not start
Check room fan wiring connected correctly
Heater shuts down after 90 seconds
Check that thermistor is in supply air / heated duct
and located approximately 3m from heater.
IMPORTANT: Must not be in the return air duct.
All checks OK but still does not start
Disconnect power, wait 5 minutes and start again