![SEELEY INTERNATIONAL Braemar Ecostar TQ3 Скачать руководство пользователя страница 16](http://html.mh-extra.com/html/seeley-international/braemar-ecostar-tq3/braemar-ecostar-tq3_installation-manual_1233143016.webp)
FAN
SPEED
INCREASE
DECREASE
SYSTEM SETUP TQ3
TQ3 Heaters
Turn the heater on at the Controller and allow to run for 5-10 minutes to reach operating temperature.
Check the air flow from all outlets.
If required, carefully adjust the fan speed by turning the trimpot located on the ICS board (alongside the Wall Control connection
terminal).
Fully clockwise = fan speed 10
Fully anti-clockwise (3/4 turn) = fan speed 7
15
TQ3, TQ4, TQ5, TQM5, TQM6, TQS3, TQS4, TQS5, TQS6
SYSTEM SETUP USING THE MAGIQTOUCH CONTROLLER TQ4, TQ5, TQM6, TQS3, TQS4,
TQS5, TQS6
TQ4, TQ5, TQM6, TQS3, TQS4, TQS5, TQS6 Heaters
Before turning the MagIQtouch Controller on ensure all components have been connected to the system.
It is very important when stepping through the Wall Control system installation wizard that you follow each prompt carefully to ensure
that the system is configured correctly.
NOTE: if you have multiple evaporative coolers refer cooler installation manual.
ADJUSTING MAXIMUM FAN SPEEDS AFTER SYSTEM SETUP
TQ3,
TQ4, TQ5, TQM6, TQS3, TQS4, TQS5, TQS6 Heaters
Fan speeds can be adjusted after the system setup if required from the SETTINGS menu. The option is found under the HEATER
heading tab.
Fan speed adjustment can only be accesed with a service pin code. The pin is 7378.
Air flow rates guide
- Ceiling 50 - 70 l/s
- Floor 45 - 55 l/s
Based on 150mm diameter outlet