TQ3, TQ4, TQ5, TQM5, TQM6, TQS3, TQS4, TQS5, TQS6
HEATER CONFIGURATION
Swapping inlet & outlet panels
The heater side panels can be moved to suit a range of installations.
To do this:
Remove heater top panel.
Remove the screws securing the side/end panels that are to be
changed.
Remove the side panels.
Move the inner metal insulation panel to the side or end of the
heater to ensure a twin skin sheetmetal layer is maintained.
Secure the side panels in their required new positions and re-fit the
heater lid.
Check that all panels are secure and that screws are tight.
IMPORTANT:
Increase the diameter of the air inlet spigot and the
full run of inlet duct by 50mm to maintain the original air flow rate if
it is moved from the open side to the motor side of the room fan.
IMPORTANT:
The air inlet panel must be fitted to the side of the
heater - do not fit the air inlet panel to the end of the heater.
Standard External Configuration
Reversed External Configuration
Preferred Internal Configuration
Increase inlet
spigot and duct
diameter by
50mm
SPLITTING AND RE-CONNECTING THE
HEATER
Heaters can be split in two (remove fan box) to assist in lifting
heaters into ceilings and moving the heater into position:
Splitting the heater
Remove the heater top panel.
Disconnect the wiring loom at the plug near the top of the centre
panels.
Disconnect the combustion fan suction hose connected to
pressure switches or hose connector depending on heater model.
Disconnect the ignition lead, flame sense lead and flame
rollout lead from the ICS PCB and feed through the grommet in the
centre panel. This is easiest to do with the grommet removed from
the panel.
Remove the two retaining screws near the top of the centre panels
from the room fan end of the heater.
Lift the room fan end of the heater to disengage from the locating
tabs near the bottom of the centre panel.
Separate the two halves of the heater.
HEAT EXCHANGER
END OF HEATER
ROOM FAN
END OF HEATER
COMBUSTION
FAN SUCTION
HOSE
WIRING LOOM
PLUG & SOCKET
ROOM FAN
END OF HEATER
HEAT EXCHANGER
END OF HEATER
PRESSURE SWITCH
SUCTION CONNECTIONS
LOCATING
TABS
RETAINING
SCREWS
Re-connecting the heater
Hook locating tabs into slots near bottom of centre panel.
Re-fit 2 retaining screws near top of centre panel.
Re-connect the combustionfan suction hose connected to
pressure switches or hose connector depending on heater model
Re-connect wiring loom plug into socket.
Re-connect the ignition lead, flame sense lead and flame
rollout lead to the ICS PCB. Ensure any grommets are correcty
re-fitted if they were removed.
Re-fit heater top panel.
TEST THE HEATER ONCE
RE-CONNECTION HAS BEEN
COMPLETED
RE-FIT 2
RETAINING
SCREWS
ENSURE TABS ARE LOCATED
IN SLOTS AT BOTH SIDES
HOOK LOCATING TABS
INTO SLOTS