Performing measurements
46
Step Description
For 10-point search
For free search
Perform measurements at all other
measuring points.
Result:
Finally, the minimum values of
the ten measurements are displayed
side by side on the screen.
The drop icon indicates the highest
value.
If the new value is lower than the
previous one, delete it with the
button.
If the new value is higher than the
previous value, keep it on the display
and mark the measuring point.
Find a new measurement point for
the next measurement, etc.
Result:
In this way, you will gradually
approach the point where the leak
noise can be heard loudest.
There is room for a maximum of 10 measurements in the display area, after which the
oldest measurement falls out of the view as soon as a new measurement is added.
The last ten seconds of each individual measurement are automatically buffered as an
audio file together with the minimum level of this measurement in the HLE 7000.
After ending and saving the pinpointing procedure, the audio files of the ten saved
measurements can then be recalled and played back.
10 values can be
displayed
Audio recording