10
Rev. 3.0 13/06/16
LED when flashing and press the SET button: the ALL MOT.
CODE LED remains lit in a constant manner and programming
is complete. This allows to obtain Operator Present type op-
eration for the first 2 seconds, using both the radio control and
the push button panel. This way it is possible to execute slight
rotations in one direction or another for Venetian reeds in order
to modulate light filtering at will. If the controls given are greater
than 2 sec. the automatic blind ascent or descent movement is
obtained, depending on the key pressed.
Repeat the procedure to restore the previous configuration.
C) CODE MOT. 1
(Automatic Movements Lock):
The control unit allows to Lock Automatic movements (Ascent /
Descent of the blind controlled by the Sun Sensor). If during
movement, a Stop control is given via radio control, the control
unit temporarily blocks Automatic movements until the following
Ascent or Descent control is given. In the control unit is sup-
plied by the manufacturer the Automatic movements Lock is
disabled; to enable the function proceed as follows: check that
the extended menu 1 is enabled (WIND SPEED LEDs and
SUN/RAIN INPUT LEDS start flashing alternately), use the SEL
button to navigate to the CODE MOT. 1 LED when flashing and
press the SET button: the MOT. 1 CODE LED remains lit in a
constant manner and programming is complete. Repeat the
procedure to restore the previous configuration.
D) CODE MOT. 2 ( Definition of the two input modes with
Synchronised Motor Operation ) :
When Synchronised Motor operational mode is selected ( Main
menu SYNC MOTORS Led = ON ), the control unit is supplied
by the manufacturer with the following control input association.
Definition 1; Synchronised Motors input:
T1 = Sun or Rain Sensor Input (N/A)
T2 = Wind Sensor Input (N/A)
T3 = MOT. 1 Ascent Local MOT. 2 (N/A)
T4 = MOT. 1 Descent Local MOT. 2 (N/A)
If wanting to modify input operation as follows. Definition 2;
Synchronised Motors input:
T1 = MOT. 1 Ascent Local MOT. 2 (N/A)
T2 = MOT. 1 Descent Local MOT. 2 (N/A)
T3 = MOT. 1 Ascent General MOT. 2 (N/A)
T4 = MOT. 1 General Local MOT. 2 (N/A)
proceed as follows: check that the extended menu 1 is enabled
(WIND SPEED LEDs and SUN/RAIN INPUT LEDS start flash-
ing simultaneously), use the SEL button to navigate to the
MOT.2 CODE LED when flashing and press the SET button:
the MOT. CODE LED remains lit in a constant manner and
programming is complete. Repeat the procedure to restore the
previous configuration.
E) CODE SENS. ( Definition of the two input modes with
Independent Motor Operation ) :
When Independent Motor operational mode is selected ( Main
menu SYNC MOTORS Led = OFF), the control unit is supplied
by the manufacturer with the following control input association.
Definition 1; Independent Motors input:
T1 = Sun or Rain Sensor Input (N/A)
T2 = Wind Sensor Input (N/A)
T3 = MOT. 1 Ascent/Descent Cyclical Button (N/A)
T4 = MOT. 2 Ascent/Descent Cyclical Button (N/A)
If wanting to modify input operation as follows. Definition 2; In-
dependent Motors input:
T1 = MOT. 1 Ascent Button (N/A)
T2 = MOT. 1 Descent Button (N/A)
T3 = MOT. 2 Ascent Button (N/A)
T4 = MOT. 2 Descent Button (N/A)
proceed as follows: check that the extended menu 1 is enabled
(WIND SPEED LEDs and SUN/RAIN INPUT LEDs start flash-
ing alternately), use the SEL button to navigate to the SENS.
CODE LED when flashing and press the SET button: the
SENS. CODE LED remains lit in a constant manner and pro-
gramming is complete. Repeat the procedure to restore the
previous configuration.
EXTENDED MENU 2
The control unit is supplied by the manufacturer with the option
of selecting only the functions listed in the main menu.
To enable the functions of extended menu 2, proceed as fol-
lows: access extended menu 1 (as described in the corre-
sponding paragraph), then press the SET button again and
hold for 5 seconds; the WIND SPEED LEDs and SUN/RAIN
INPUT LEDs will flash simultaneously: the user has 30 seconds
within which to select the functions of extended menu 2 using
the SEL and SET buttons. Then after a further 30 seconds the
control unit returns to the main menu.
---------------------- EXTENDED MENU 2 -----------------
LED Reference LED Off LED On
A) SYNC MOTORS Wire Sensors Test = OFF Wire Sensors Test =
ON
B) CODE ALL MOT. Safety Ascent = OFF Safety Ascent = ON
C) CODE MOT. 1 WIND Inversion = OFF WIND Inversion = ON
D) CODE MOT. 2 SUN Inversion = OFF SUN Inversion = ON
E) CODE SENS. RAIN Inversion = OFF RAIN Inversion = ON
F) WIND SPEED Flashing light ON/OFF simultaneous
G)SUN/RAIN INPUT Flashing light ON/OFF simultaneous
A) SYNC MOTORS (Test Wire Sensors Test):
The control unit allows to check the operation of the connected
Sensors and that they are rotating in the correct direction. Upon
installation we suggest to put the blind in an intermediate posi-
tion in order to check the confirmation movements during the
tests. After verifying the correct functioning of the Sensors, it
is necessary to disable the Wire Sensors Test.
Wired Anemometer Test:
manually turn the blades of Ane-
mometer, at the same time the control unit will trigger ascent for
5 sec.
Wired Sun Sensor Test:
expose the Sun Sensor to the sun or
a light source: at the same time the control unit will cause the
SUN/RAIN INPUT LED to flash quickly and descent for a time
equal to 5 sec. Obscure the Sun sensor, at the same moment
the control unit will cause SUN/RAIN INPUT LED to flash slow-
ly and the ascent for a time of 5 sec.
Wired Rain Sensor Test:
wet the sensitive part of the Rain
Sensor and, at the same time, the control unit will cause the
SUN/RAIN INPUT LED to flash and the ascent for a time of 5
sec. Once completed the test, ensure the sensitive part of the
rain sensor has been dried before using the control unit as part
of the normal operations of the product.
Programming:
The control unit is supplied by Wire Sensors
Test disabled. To enable the Wire Sensors Test, proceed as
follows: check that the extended menu 2 is enabled (WIND
SPEED LEDs and SUN/RAIN INPUT LEDs start flashing simul-
taneously), use the SEL button to navigate to the SYNC
MOTORS LED when flashing and press the SET button: the
SYNC MOTORS LED remains lit in a constant manner and
programming is complete. Repeat the procedure to restore the
initial configuration.
Important:
for the Wireless Sensors test please refer to the
Wireless Sensor's manual.
B) CODE ALL MOT. (Safety Ascent):