40
Intensity
This function sets the light intensity. Valid intensity values are 1 for 25%, 2 for 50%, 3 for 75% and
4 for 100%.
Example Key sequence:
This sets the light intensity to 25%.
Battery Status
This function reads the battery status. The response from the light is High Voltage: 4 fl ashes,
Good Voltage: 3 fl ashes, Low Voltage 2 fl ashes, Cutoff Voltage or below: 1 fl ash.
I
I
1
T/C
T/C
B
R
B
T/C
T/C
Flash Code Numbers
The lamp fl ashes numbers as follows: Hundreds, Tens, Ones. A value of 125 will be fl ashed as: 1 fl ash,
followed by a delay, 2 fl ashes, followed by a delay, 5 fl ashes.
The fl ash for number 0 is one long fl ash.
For example if the current Flash Code is set to 51 via the AB switches, the lamp will fl ash number 081.
For a Flash Code set to 01, the lamp will fl ash 001.