INSTALLATION
MANUAL
Product:
Document #:
Rev:
Page:
SEAKEEPER 9 / 7HD
90222
6
4 of 11
Section 2: ELECTRICAL INSTALLATION
3. DRIVE BOX AC POWER OUTPUT TO SEAWATER PUMP CONNECTION
INSTRUCTIONS
a. Cable: 3 x 14AWG (3 x 2.5 mm
2
CSA) cable, 10’ (3m) length, Seakeeper supplied
pre-installed.
b. Pumps rated at 230 VAC, 5 Amps max., Customer-supplied.
i. Locate CABLE 5 for AC power output to the Seawater Pump from the Drive
Box at the middle of three cable glands. (See Figure 2.)
FIGURE 4
– CABLE 5, AC OUTPUT POWER CABLE
ii. Connect the 230 VAC wires in CABLE 5 to a 5 Amp maximum, Seawater
Pump (approximately 1/3 horsepower or 250 W) according to Figures 4 and 5.
FIGURE 5
– CABLE 5, WIRE CONNECTIONS TO SEAWATER PUMP
c. If the customer-supplied Seawater Pump is not rated for 230 VAC, the CABLE 5
output may be used to switch a customer-supplied relay.
i. Locate CABLE 5 for AC power output to the Seawater Pump from the Drive
Box at the middle of three cable glands as shown in Figure 2.
Verify that AC power is OFF to the Drive Box before connecting
CABLE 5 to a Seawater Pump.