INSTRUCTIONS
Page 2 of 4
Product: ALL
Document #: 90213
Process: Plexus PC- 120 Application Instructions
Rev.: 1
1)
Using too much PC-120
•
Only a very thin coat should be left on the metal. You should be able to see a slight “pink” cast
as illustrated below.
Too Much PC-120
Correct Amount
2)
Not removing oils once primed
Wipe the surface with a dry rag
•
The solvents in PC-120 will
clean and “lift” most
machining oils, but if the
metal isn’t wiped clean of
these oils then they will be
deposited right back onto
the metal surface when
the solvent in PC-120
evaporates!
•
While still wet, wipe the
PC-120 applied to the
surface with a clean dry
paper towel, changing the
paper towel as needed.
Replace the rag when dirty
•
Notice how much aluminum oxide was cleaned off “clean” looking Aluminum