SEA JOINT Скачать руководство пользователя страница 3

3

GENERAL SAFETY INFORMATION 

An appliance shall be provided with an instruction manual. 
The instruction manual shall give instructions for the installation, operation, and user maintenance of the appliance. 
The installation instructions shall specify the need for a grounding-type receptacle for connection to the supply and 
shall stress the importance of proper grounding.
The installation instructions shall inform the installer that permanent wiring is to be employed as required by local 
codes, and instructions for conversion to permanent wiring shall be supplied.

I

NFORMATION

 

SHALL

 

BE

 

SUPPLIED

 

WITH

 

A

 

GATE

 

OPERATOR

 

FOR

:

   a.

 

The required installation and adjustment of all devices and systems to effect the primary and secondary protection  

       against entrapment (where included with the operator).

   b. The intended connections for all devices and systems to effect the primary and secondary protection against en-
      trapment. The information shall be supplied in the instruction manual, wiring diagrams, separate instructions, or the
      equivalent.

V

EHICULAR

 

GATE

 

OPERATORS

 (

OR

 

SYSTEMS

)

A vehicular gate operator shall be provided with the information in the instruction manual that defines the different 
vehicular gate operator Class categories and give examples of each usage. The manual shall also indicate the use for 
which the particular unit is intended as defined in Glossary, Section 3. The installation instructions for vehicular gate 
operators shall include information on the Types of gate for which the gate operator is intended.
A gate operator shall be provided with the specific instructions describing all user adjustments required for proper 
operation of the gate. Detailed instructions shall be provided regarding user adjustment of any clutch or pressure relief 
adjustments provided. The instructions shall also indicate the need for periodic checking and adjustment by a qualified 
technician of the control mechanism for force, speed, and sensitivity.
Instructions for the installation, adjustment, and wiring of external controls and devices serving as required protection 
against entrapment shall be provided with the operator when such controls are shipped with the operator.
Instructions regarding intended installation of the gate operator shall be supplied as part of the installation instructions 
or as a separate document. The following instructions or the equivalent shall be supplied where applicable:

IMPORTANT INSTALLATION INSTRUCTIONS

1. 

Install the gate operator only when:

a. The operator is appropriate for the construction of the gate and the usage Class of the gate
b. All openings of a horizontal slide gate are guarded or screened from the bottom of the gate to a minimum of 4 feet 

(1.22 m) above the ground to prevent a 2-1/4 inch (57.2 mm) diameter sphere from passing through the openings 
anywhere in the gate, and in that portion of the adjacent fence that the gate covers in the open position

c. All exposed pinch points are eliminated or guarded
d. Guarding is supplied for exposed rollers

2.

 The  operator  is  intended  for  installation  only  on  gates  used  for  vehicles.  Pedestrians  must  be  supplied  with  a 

separate access opening. The partial access opening shall be designed to promote pedestrian usage. Locate the gate 
such that persons will not come in contact with the vehicular gate during the entire path of travel of the vehicular gate.

3.

 The  gate  must  be  installed  in  a  location  so  that  enough  clearance  is  supplied  between  the  gate  and  adjacent 

structures when opening and closing to reduce the risk of entrapment. Swinging gates shall not open into public access 
areas.

4.

 The gate must be properly installed and work freely in both directions prior to the installation of the gate operator. Do 

not over-tighten the operator clutch or pressure relief valve to compensate for a damaged gate.

5.

 The gate operator controls must be placed so that the user has full view of the gate area when the gate is moving and 

AWAY FROM THE GATE PATH PERIMETER.

6.

 Controls intended for user activation must be located at least six feet (6’) away from any moving part of the gate and 

where the user is prevented from reaching over, under, around or through the gate to operate the controls. Outdoor or 
easily accessible controls shall have a security feature to prevent unauthorized use.

7.

 The Stop and/or Reset button must be located in the line-of-sight of the gate. Activation of the reset control shall not 

cause the operator to start.

8. 

A minimum of two (2) WARNING SIGNS shall be installed, one on each side of the gate where easily visible

9. F

OR

 

GATE

 

OPERATORS

 

UTILIZING

 

A

 

NON

-

CONTACT

 

SENSOR

:

a. See instructions on the placement of non-contact sensors for each Type of application 

 

   

b. Care shall be exercised to reduce the risk of nuisance tripping, such as when a vehicle, trips the sensor while the 

gate is  still moving

c. One or more non-contact sensors shall be located where the risk of entrapment or obstruction exists, such as the   

perimeter reachable by a moving gate or barrier

Содержание JOINT

Страница 1: ...UPER FULL TANK 20 40 HYDRAULIC OPERATOR FOR SWING GATE REV 03 11 2020 SEA USA Inc 10850 N W 21st unit 160 DORAL MIAMI Florida FL 33172 Phone 1 305 594 1151 Toll Free 800 689 4716 www sea usa com 67411857 ...

Страница 2: ...operator 10 In case of break down or malfunctioning of the product disconnect from the main power source Do not attempt to repair or intervene directly contact only qualified personnel for repair 11 Failure to comply with the above may create a situation of danger 12 All cleaning maintenance or repair work must be carried out by qualified personnel 13 In order to guarantee that the system works ef...

Страница 3: ...d where applicable IMPORTANT INSTALLATION INSTRUCTIONS 1 Install the gate operator only when a The operator is appropriate for the construction of the gate and the usage Class of the gate b All openings of a horizontal slide gate are guarded or screened from the bottom of the gate to a minimum of 4 feet 1 22 m above the ground to prevent a 2 1 4 inch 57 2 mm diameter sphere from passing through th...

Страница 4: ...uction SEA USA Inc can not be deemed responsible for any damage or accident caused by product breaking being damages or accidents due to a failure to comply with the instructions herein The guarantee will be void and the manufacturer responsibility will be nullified if SEAUSAInc original spare parts are not being used The electrical installation shall be carried out by a professional technician wh...

Страница 5: ...placement of external devices but they give only examples of suggested entrapment protection in their installation manuals If the installer identifies a risk of entrapment or obstruction at least two independent means of entrapment protection are required 4 TERMINOLOGY CHANGE The terms primary and secondary have been removed in the description of entrapment protection devices This was done to emph...

Страница 6: ... the factory for instructions and authorization Merchandise returned for credit must becurrent uninstalledandunusedandreturnedinitsoriginalpackaging Freightmustbepre paidonallauthorizedreturns REPAIRS Repairsandpartsaresubject totheavailability instock Shipmentofproducts forrepairs must bepre paidbythecustomer Products shippedwithoutauthorization sender sdetailsanddescriptionoftheproblemswillberef...

Страница 7: ...se of the electric lock on operators without block SB moreover the exclusion of electronic slowdown is recommended in case of operators with hydraulic slowdown 5 Cylinder 6 Electric motor 7 Hydraulic pump 8 Electric cable 29 53 ft 70 40 Fig 2 SUPER FULL TANK 20 G6 380V SFT 20 G6 380V SUPER FULL TANK 20 G6 120V SFT 20 G6 120V Fig 1 19 69 39 37 4 33 2 64 61 81 100 79 60 04 100 55 SUPER FULL TANK 40 ...

Страница 8: ...rent Stroke Shaft speed Cycles per hour at 68 F Max working pressure Operating temperatures Thermal protection Max Thrust Capacitor Weight rotection class P Max leaf lenght Opening degree of the leaf SUPER FULL TANK 20 G6 380V SUPER FULL TANK 20 G6 120V TECHNICAL FEATURES SUPER FULL TANK 40 G4 120V The frequency of use is valid only for the first working hour and at 68 F temperature If operator wo...

Страница 9: ...8 7 28 6 69 7 09 6 50 6 30 6 69 5 91 5 51 5 12 3 15 4 72 3 35 4 92 3 94 5 51 5 71 4 72 6 30 4 92 6 50 6 69 5 51 7 09 7 48 7 87 6 18 6 18 6 18 6 18 6 18 6 18 6 18 6 18 6 18 6 18 6 18 6 18 6 18 6 18 6 18 6 18 16 93 16 93 17 32 17 72 17 72 18 50 18 90 18 90 18 90 18 90 18 90 18 90 18 90 18 90 18 90 18 90 18 90 18 90 18 90 18 90 18 90 18 90 inches inches inches inches SUPER FULL TANK 20 SUPER FULL TAN...

Страница 10: ...loose the parts listed in Fig 5 2 For a proper operation it is important to place as the operator as the front and rear brackets in a perfectly horizontal position with the help of a level as shown in Fig 10 Level REAR BRACKET INSTALLATION PRELIMINARY NOTES Fig 10 REAR BRACKET INSTALLATION The rear bracket must first be cut by respecting the a dimension shown on page 9 then welded Fig 13 The rear ...

Страница 11: ...rocedure in Fig 34 and Fig 35 2 Pull out completely the chrome shaft then bring it back about 0 4 inches 3 Place the front bracket on the gate and place the shaft in the housing Fig 17 4 With the help of a level Fig 16 make sure that the operator is in a perfectly horizontal position then mark the front bracket position Fig 17 FRONT BRACKET INSTALLATION Level Fig 16 Fig 17 Fig 18 Fig 19 SCREWED FR...

Страница 12: ...l the successive adjustments of the valves eg periodic maintenance should be made by unscrewing completely the external manual release see page 13 then make adjustments as shown in Fig 25 The opening and closing forces transmitted to the gate by the motor pump assembly are regulated by adjusting two by pass valves the grey valve adjusts the opening pressure while the yellow valve adjusts the closi...

Страница 13: ...MENT The oil level should be measured with the shaft inserted into the operator The oil level must correspond to the level of the distributor surface OIL LEVEL Fig 31 Fig 33 Fig 32 DISTRIBUTOR LEVEL DISTRIBUTOR UNSCREW AND LIFT THE MANUAL RELEASE THREE PHASE CABLE CONNECTIONS 1 PHASE 1 U 2 PHASE 2 V 3 PHASE 3 W 4 MOTOR HEATING DETECTOR CONTACT NC 5 MOTOR HEATING DETECTOR CONTACT NC 6 GROUND YELLOW...

Страница 14: ... 2 Check the oil level the oil cap is under the manual release 3 Replace the hydraulic oil with the oil recommended by the producer 4 Check the function of the release 5 Check the function of the by pass valves 6 Check and grease the fixation pins 7 Check the integrity of the connecting cables 8 Check the function and the conditions of the mechanical stops in opening and closing where the mechanic...

Страница 15: ...l be void and the manufacturer responsibility will be nullified if original spare parts are not being used SEA USA Inc The electrical installation shall be carried out by a professional technician who will release documentation as requested by the Laws in force Packaging materials such as plastic bags foam polystyrene nails etc must be kept out of children s reach as dangers may arise Internationa...

Страница 16: ...SEA USA Inc 10850 N W 21st unit 160 DORAL MIAMI Florida FL 33172 Phone 1 305 594 1151 Toll Free 800 689 4716 www sea usa com sales sea usa com ...