11
- Mount the oscillating fork on the rear bracket, then secure the fixing pin as shown in Fig. 14
DO NOT incline the hydraulic operator
further than the oscillating fork allowed angle (
1
), it
may cause its breaking (Fig. 15)
DO NOT use the hammer
to insert the short brass pin; its fitting into the fork and the bracket
must be get by the simple pressure of the hands
INSTALLATION OF THE OSCILLATING FORK ON THE REAR BRACKET
Fig. 14
Fig. 15
(1)
Once the operator has been fixed on the rear bracket, close the leaf and proceed as follows:
1) Release the operator (see the releasing procedure in Fig. 34 and Fig. 35)
2) Pull out completely the chrome shaft,
then bring it back about 0,4 inches
3) Place the front bracket on the gate and place the shaft in the housing (Fig. 17)
4) With the help of a level (Fig. 16),
make sure that the operator is in a perfectly horizontal position
then
mark the front bracket position (Fig. 17)
FRONT BRACKET INSTALLATION
Level
Fig. 16
Fig. 17
Fig. 18
Fig. 19
SCREWED FRONT FIXATION
1,85'’
5,40'’
2,76'’
1,93'’
5,55'’
3,54'’
5,40'’
SUPER
FT
20
5,55"
SUPER
FT
40
WELDED FRONT FIXATION
SUPER
FULL
TANK
20
SUPER
FULL
TANK
40
DO NOT WELD THE FRONT FIXATION WITH THE SHAFT ALREADY INSERTED!
The welding scraps (squirts) could damage the shaft chrome plating
DEPENDING
ON
THE
GATE
MATERIAL
(
WOOD
,
IRON
,
ALUMINIUM
)
THE
FRONT
FIXATION
CAN
BE
SCREWED
OR
WELDED
Fig. 20