13
Fig. 28
Fig. 27
2 - Mount the release
1 - Remove the transporting plate
EXTERNAL RELEASE MOUNTING
BREATHER
SCREW
WARNING
:
It is obligatory to remove the breather screw at the end of the installation
Fig. 29
Fig. 30
BREATHER SCREW
Unscrew
and take off
at
the end of
the installation
OIL LEVEL MEASUREMENT
The oil level should be
measured with the shaft
inserted into the operator.
T h e o i l l e v e l m u s t
correspond to the level of
the distributor surface
O
IL
LEVEL
Fig. 31
Fig. 33
Fig. 32
DISTRIBUTOR
LEVEL
DISTRIBUTOR
UNSCREW
AND
LIFT
THE
MANUAL
RELEASE
THREE-PHASE CABLE CONNECTIONS
1 - PHASE 1 (U)
2 - PHASE 2 (V)
3 - PHASE 3 (W)
4 - MOTOR HEATING DETECTOR CONTACT (NC)
5 - MOTOR HEATING DETECTOR CONTACT (NC)
6 - GROUND - YELLOW/GREEN (GV)
1
2
3
4
5
6
NOTE
The release key is
kept in a special
housing inside the
release lid