START (N.O.)
An impulse given to this contact opens and closes the automation depending on logic selected. It can
be given by a key switch, a keypad, etc.
To connect the other devices refer to the related instructions leaflets. (ie. loop detectors and proximity
switches)
Note1: In manual logic it is necessary to keep pressed the Start for the opening of the leaf.
PEDESTRIAN START (N.O.)
To obtain a partial opening (only one leaf opening) connect the key-button wires as in the picture. It is
possible to connect other command devices (push button board, radio receiver, keypad).
From the display it is possible to adjust the pedestrian opening space: 30%, 50%, 100%.
Note1: The contact for partial opening is a N.O. Contact (Normally open)
Note2: Partial opening will always operate the
M1
motor.
Nota3: In manual logic it is necessary to keep pressed the Start Ped. for the reclosing of the leaf.
STOP (N.C.)
The pressure on this button immediately stops the motors in any condition /position. A start
command is needed to re-start movement.
After a stop the motors always re-start in closing.
Notice: If stop button is not used make a jumper between terminals n° 1 and 2 of M12.
ANTENNA
Connect the antenna
as in the picture.
START - STOP - PEDESTRIAN START - ANTENNA -
PHOTOCELL
1
2
1
2
M16
GND
Photocell 1 Connection
When the ray of the photocell is crossed, and the automation is in
phase of closing it reverses its movement. Through programmer
JOLLY it is possible to activate the photocell in opening, if activated
it causes the interruption of the movement as long as it is busy, for
then continuing the opening as soon as it is released.
Note: If the photocell is not connected, put a jumper between
the clamps 1 and 2 of (M9).
+ = 24V - = 0V C = Connection
Com = Common
The photocell is also usable in connection with BUS photocells.
1 2
1 2
M5
RX
TX
Co
m
N.C.
1
2
1
2
M9
-
+
-
+
-
JOLLY OPTIONS
FOTOCLOSE activation
: If activated when the photocell
is crossed during the pause, the gate interrupts the pause and
immediately closes again.
TIMER activation
: If the entry is activated it turns into a N.O. entry
with TIMER function (see TIMER)
N.O.
-
1
2
1
2
M10
N.C.
-
1
2
1
2
M12
N.O.
-
1
2
1
2
M7
Can be activated through the Jolly programmer or modifying either the PHOTO entry or the PEDESTRIAN entry.
In both cases it’s a N.O. Contact which provoques the opening of the leaves keeping them open until it is
activated. When it’s released, the gate attends the set pausing time and executes the reclosing.
Note2
: When activated on the pedestrian entry, the pedestrian will be disabled also on the radio transmitter.
Note3
: In case of intervention of a security device during the timer (Stop, Ammeter, Edge), to restore the
movement it will be necessary to give a start impulse.
Note4
: In case of no power supply if during restoration a TIMER is activated, the automation executes the
closing and the re-opening of the leaves restoring automatically the TIMER function.
+ 24V
JOLLY OPTIONS
Activation TIMER
: this entry can be transformed into TIMER (See TIMER)
TIMER
JOLLY OPTION
67410925
9
USER 2 - 24V
International registered trademark n. 2.777.971
M
5
M
7
M
9
1
M
0
M
12
1
M
6
REV 02 - 06/2010