Cycle Semiaut./manual/automatic/security
Double/single leaf Select double or single leaf
Time of pause [0÷120]s (time of pause in seconds)
Encoder on/off (function with encoder, not implemented)
The Jolly programmer allows to keep under control all the parameters of the control unit and it results essential for the initial
setting of some parameters, which are: pre-flashing, photocell self-testing, photocell in opening, anti-intrusion, torque motore1
and 2, deceleration speed, learning speed, acceleration, deceleration, leaf stroke, number of cycles, pedestrian opening, etc.
Screen 2
Screen 4
Screen 5
Screen 3
Motor (Field/Alpha) (Flipper) (Beta)
Screen 1
Language: Italian With b and - it is possible to modify the language
The arrow shows that the
parameter is modifiable with the
b and -
Screen 6
Screen 7
Screen 8
Note
: The alignment appears only if
photocells are present on the BUS.
Note
: Hydraulic/barrier on
USERHIDRO
Learning on alignment/off (signalling of the execution of
the learning)
32
Cicli exec. [0÷2 ] (number of executed cycles)
Mem. free [0÷100]% (percentage of available
memory for the learning of remote controls)
Indicates the type of motor set
Speed [30÷100 ] adjusts the motors’ speed
Sl. speed [30÷100 ] adjusts the slow down speed
Lear. Speed. [30÷100 ] adjusts the learning speed
Photocell Tx1 [OK-NP] (peripheral reveal - not present)
Photocell Tx2 [OK-NP] (peripheral reveal - not present)
Photocell TX3 [OK-NP] (peripheral reveal - not present)
Photocell TX4 [OK-NP] (peripheral reveal - not present)
Photocell TX5 [OK-NP] (peripheral reveal - not present)
Photocell Rx1 [OK-NP] (peripheral reveal - not present)
Photocell RX2 [OK-NP] (peripheral reveal - not present)
Photocell Rx3 [OK-NP] (peripheral reveal - not present)
Photocell RX4 [OK-NP] (peripheral reveal - not present)
Photocell RX5 [OK-NP] (peripheral reveal - not present)
S h o w s t h e w o r k i n g l o g i c
adjusted on board of the control
unit.
The screens
4
,
5
,
6
,
7
,
8
and
9
show the type of accessory on the
BUS.
PROGRAMMER JOLLY PARAMETERS ADJUSTMENT
67410925
16
USER 2 - 24V
International registered trademark n. 2.777.971
REV 02 - 06/2010