10/01
21
14. "" O
OUTPUTS "" M
MENU
After validation using the V button, when the cursor flashes over the o sign next to Outputs, the OUTPUTS screen appears as follows.
5 lines can be displayed at the same time on the screen.
The cursor flashes on the o sign of the first line.
Press
to move the cursor to the next line, unless the cursor is on the Option 55 m
module.
Press to move the cursor to the previous line, unless the cursor is on the Main bboard ((CB).
Press
or
to place the cursor on the desired display.
Press V when the cursor flashes on the o sign of one of the 6 lines to display the logical status
of the outputs on interface board CB or CB12, and the outputs on both option 3, 4 and 5 modules,
as described below:
- The outputs are numbered on the first line and the flashes on output 1.
- The next two lines indicate the logical status (0 or 1), symbolized by an asterisk (*).
- The last two lines indicate the cursor position and output wording.
This simple principle is used to display, in real time, how the system inputs change.
The option 5 module is simply module OPT34 configured as module 5. This module is program-
med specifically for applications with engines using integrated control electronics (MTU and Cummins engines).
The selection parameter for this module already exists in software version 1.01B. However, a line has been added in the INPUTS and OUTPUTS screens
to display the logical status of the inputs and outputs of the module in accordance with its programming.
Composition oof tthe iinterface bboards ((logical ooutputs)
CB board
(7 outputs)
CB12 board = CB board + option 1 + option 2
(7 o 3 o 2 outputs)
CB12 BOARD
CB BOARD
Main bboard ((CB)
Logical status display of the outputs on interface board CB, i.e. the seven outputs described in Section
" Technical characteristies ".
Note: the seven outputs are also available on interface boards CB12.
MAIN BOARD (CB)
Esc: Exit
1234567
0: * * * * * * *
1:
Output 1:
Fuel Solenoid Control
Option 11 ((CB1/CB12)
Logical status display of the outputs on option 1 part of interface board CB12, i.e. the three outputs
described in Section " Technical characteristies ".
Note: the three outputs are also available on interface board CB12.
OPTION 1 (CB1/CB12)
Esc: Exit
123
0: ***
1:
Output 1:
Air Damper Control
sc: Exit
CB12)
o Option 4 Module
o Option 5 Module
INPUTS
V:
Valid
Esc: Exit
o Main
board
(CB)
o Option 1 (CB12)
o Option 2 (CB12)
o Option 3 Module
o Option 4 Module
Option 22 ((CB12)
Logical status display of the outputs on option 2 part of interface board CB12, i.e. the two outputs des-
cribed in Section " Technical characteristies ".
OPTION 2 (CB12)
Esc: Exit
12
0:
**
1:
Output 1:
Fuel Pump Control
Option 33 M
Module
Logical status display of the ten outputs on option 3 module.
As these outputs can be programmed, the wording on each line varies according to the programming
performed. For that reason, the wording does not appear on the screen opposite.
OPTION 3 MODULE
Esc: Exit
123456789 10
0:
* * * * * * * * * *
1:
Output 1: