P:\INSTALLATION INST\Access Control\INST-936.vsd 0106 Page 10
NORMAL SYSTEM OPERATION
When the system is first powered up (or when communication is broken between the Keypad
and the Control Module), the PROGRAM button in the Control Module must be pressed to
establish the encoded connection. This also puts the system into setup mode. To end, press
* * to exit. Or, the system will automatically exit programming if no entries are made for 30
seconds.
KEYPAD LED STATUS INDICATORS
A flashing green LED indicates that the door is unlocked (momentarily).
A solid green LED indicates that the door is unlocked (latched).
A solid red LED indicates that the door is locked.
Depending on how the System Options are configured, User Commands are used to operate
Manual Latching. The User Commands are trailing digits entered after an authorized user
code. The ability to use these User Commands depends on authorizations assigned to each
User (see pages 18-19).
As the Main Output activates, the green LED will flash for 5 seconds. While the green LED is
flashing, enter one (or more) of the following User Commands:
0 #
to Latch the Door Closed (Main Relay, 2
nd
Door or 3
rd
Door)
1 #
to Latch the Door Open (Main Relay, 2
nd
Door or 3
rd
Door)
2 #
to Turn Output A OFF (2
nd
Output as Aux.)
3 #
to Turn Output A ON (2
nd
Output as Aux.)
4 #
to Turn Output B OFF (3
rd
Output as Aux.)
5 #
to Turn Output B ON (3
rd
Output as Aux.)
TAMPER ALARM
An audible Tamper Alarm sounds when four incorrect code entries are made. After 30
seconds, the unit returns to standby mode.
CONTROL MODULE LED STATUS INDICATORS
Mode
Green
Red
Normal Operation
On
Off
Lockup Mode
On
Flashing
Setup Mode
Flashing
Off
Connection Problems
Off
On