P:\INSTALLATION INST\Access Control\INST-936.vsd 0106 Page 3
CONFIGURATION
PINS- “CONFIG”
KEYPAD CONNECTOR DIAGRAM
YELLOW- Door Monitor
(Do NOT apply voltage)
GRAY*
SHIELD*
VIOLET*
*Connect to Control Module inputs
NOTE: The 2x6 connector is rotated 180 degrees
VOLTAGE SELECT
(Do NOT apply voltage)
12-24V (default)- Jumper on
one pin
5V- Jumper on both pins
BLACK*-Ground
ORANGE*- Program (Do NOT
apply voltage)
RED*- Input Voltage
GREEN*- Output for Control
Module
YELLOW- Anti Tailgate
If not used, this must be connected to BLACK.
By adding a door monitor switch between
YELLOW and BLACK, the door will relock immediately after opening. If Output B is set up as
Internal Alarm, this switch will trigger the alarm if the door is opened without a code or if the door
is left open longer than the Door Ajar Time setting.
RED, BLACK, GREEN, VIOLET, GRAY, ORANGE and SHIELD –
These wires all connect to
the Control Module.
TIME CLOCK
If TIME CLOCK is enabled in Set up (page 17), when the CLOCK terminal on the Control
Module circuit is connected to ground, through time clock or other switch contacts, all codes
work normally. When the CLOCK terminal is not grounded, only those codes with 24-hour
Access Authorization (page 18) will function. The disabled codes are still considered valid and
will not trigger the Tamper Alarm if tried repeatedly.