EN
::: 43
Query phone number for SMS
message
Query first to sixth group of phone number for SMS message.
example: Send 12344001# to the alarm panel, the alarm panel replies
“Group 1 SMS number: 13888889999” means alarm the 1
st
phone number for
SMS message is 13888889999.
40
+
【
01-06
】
+
【
#
】
Query assignment of remote
control to defense zone
Query the assignment of remote control to specific defense zone
example: Send 12345401# to the alarm panel, the alarm panel replies: “01
remote control zone range:00-99,Keyboard zone range:00-99” means 01
remote control is assigned to control zone 00-99. and keyboard is assigned to
control zone 00-99.
54
+
【
00-99
】
+
【
#
】
Querying alarm panel system
time
Query alarm panel system time
example: Send 123456# to the alarm panel, the alarm panel replies
“System clock :2011-07-01 12:00”. Means the system is now 1
st
of July of 2011
12
:
00
:
00 am.
56
+
【
#
】
Check the status of scheduled
arm/disarm
Query the four group of the scheduled arm and disarm
example: 12345701# to the alarm panel, the alarm panel replies:
group 1 timing:
arm time:22:00
disarm time:07:00
Arm/Disarm week:12345
Zone range:00-99
Means: the first group scheduled time to arm at 22
:
00 pm and disarm at
07
:
00 am, this is valid for Monday, tuesday, Wednesday, thursday and
Friday of each week. control 00-99 defense zone
57
+
【
01-04
】
+
【
#
】
Check the type and siren
setting of wireless defense zone
Query the type and siren setting of certain wireless defense zone
example: Send message 12346001# to the alarm panel, the alarm panel
replies”01 zone is wireless zone, zone type: normal; siren on”
60
+
【
00-99
】
+
【
#
】
Check the settings of wired
defense areas
Query the alarm panel for settings of zone 51
-
54 wired zone.
example: send text message 12346151# to the alarm panel, the alarm panel
replies”51 zone is wired zone, zone type : normal; siren on; alarm type: no”
61
+
【
51-54
】
+
【
#
】
Query phone number
assignment to zone
Query the alarm panel the phone number assigned to zone 00-99.
example: send message 12346301# to the alarm panel, the alarm panel
replies”01 zone dialing group number:123456” means zone 1 will dial phone
group 123456.
63
+
【
00-99
】
+
【
#
】
Customize the SMS message
for certain zone
Used to customize the SMS message for zone 00-99.
example: Send message “12348001 Front door alarm#” to the alarm panel will
set alarm panel to send SMS message “Front door alarm” upon zone 01 alarm
being triggered.
note: Maximum length of message is 25 characters.
80
+
【
00-99
】
+ “panel with SMS message”
+
【
#
】
Содержание SCS1 COMFORT+
Страница 1: ...V 03 2015 Ind A S E N T I N E L KIT CENTRALE ALARME SCS1 COMFORT FR ...
Страница 25: ...V 03 2015 Ind A S E N T I N E L CENTRAL ALARM KIT SCS1 COMFORT EN ...
Страница 47: ...EN 47 ...