EN
::: 35
Scheduled arm and disarm
zones settings
Used to set when the four group of zone to be controlled by scheduled arm and
disarm
Example: To set up the first group scheduled arm and disarm control 00-50
defense zone.
Method one:
press # enter the setup status and press 58010050#, press * then press # exit
Setup
Method two:
after calling and connected to the panel from remote, press 58010050#
Method three:
Send SMS message 123458010050#
Syntax:
【
58
】
+
【
group number 01~04
】
+
【
00-99 Defense zone
begin the area code
】
+
【
00-99 Defense zone
ends area code
】
+
【
#
】
Set the type of defense zone
To set 99 zone type, 00-99 represents 0-99 zone number,
1-8 represents one of the 8 zone type:
1. norMal
2.
STAY ARM
3. intelligent
4.
EMERGENCY
5. cloSed
6. cHiMe
7. WelcoMe
8.
Help Senior
The last 0/1 represents 0 siren of panel produce no sound upon alarming while
1 is sounded.
Example: Set zone number 2 as STAY zone type, and siren not sound upon
alarming2.
Method one:
Press # enter the configuration mode, press 600220#, press * then press # To exit
Setup.
Method two:
after calling and connected to the panel from remote, press 600220#
Method three:
Send SMS message 1234600220#
Syntax:
【
60
】
+
【
00-99 zone number
】
+
【
1-8 type
】
+
【
0/1
】
+
【
#
】
Set mode of wired alarm
zone
Set wired alarm zone to NO or NC. The zone number of 51-54 are wired defense
zones, system default is 51-54 are wired zones with NO mode.
0 means no and 1 means nc
no means short-circuit to alarm
nc means open-circuit to alarm
example: Set 51 zone to nc,
Method one:
# Key enters the configuration mode, press 61511#
* then press # to exit Setup.
Method two:
after calling and connected to the panel from remote, press 61511#
Method three:
Send SMS message 123461511#
remark: on the back pane of the alarm panel
51 = zone 1 and labelled Z1
52 = zone 2 and labelled Z2
53 = zone 3 and labelled Z3
54 = zone 4 and labelled Z4
Syntax:
【
61
】
+
【
zone number 51-54
】
+
【
0/1
】
+
【
#
】