3.2 Pre-record voice Message
alarm panel will play a pre-recorded voice message after the alarm call when a pre-set phone number upon alarm.
to record customized message:
• Press “# “Key to enter the configuration mode:
• Then press 19#, speak your message at the panel for recording
• System will record 10 Seconds and then automatically exit; or press any key
to end whenever your message end.
• Press *, then # exit setup status.
3.3 Add Remote Control:
Press “#” key to enter the configuration mode:
Syntax:
07+(00~99)+#
to configure remote control
Example: 07 then press 01# , to configure the 1st remote control. then press any key of the remote control to send a
signal to the alarm panel, panel beep twice means successful, beep only once means the remote control has been
configured before. Alarm panel can configure up to 150 remote control of different addressing. Upon completion
press # to exit the configuration mode, press * and then # exit the configuration mode.
3.4 delete the remote control:
Press “# “Key to enter the configuration mode:
Syntax 1:
08+(00~99)+#
to delete the remote control
Syntax 2:
08+**+#
to delete all remote controls
example: 08 then press 01# for deleting 1st remote control, then if you want to delete 8th remote control, press “08”
instead of “01”. Press # to exit the delete remote control, press * and then # to exit configuration mode.
3.5 Add detector
Press “# “Key to enter the configuration mode:
Syntax:
09+(00~99)+#
to set the detector
Example: 09 then press 01# , to configure 1st sensor, then trigger the detector to send a signal to the alarm panel.
panel beep twice means successful, beep only once means the remote control has been configured before. Alarm
panel can configure up to 150 sensors of different addressing. Upon completion press # to exit the configuration
mode, press * and then # exit the configuration mode.
3.6 delete detector
Press “# “Key to enter the configuration mode
:
Syntax 1:
10+(00~99)+#
to delete the detector
Syntax 1:
10+**+#
to delete all detectors
example: 10 then 01#, to deleting 1st sensor. if you want to delete the 6th detectors, use “06” instead of “01”. upon
completion press # to exit the configuration mode, press * and then # exit the configuration mode.
This system supports three methods of configuration including the local keyboard, telephone set and SMS messaging.
Following are examples how instructions are given via one of the three methods of setting
Example:
you want to change the first phone number for voice calling to 13899998888:
Method 1: At the Keyboard
Press # to enter the configuration mode, and then press 3113899998888#, press the * then press # to exit configuration
mode.
Method 2: By telephone set
calling into the alarm panel, upon connected, alarm panel will ask for password, it is 1234 as the default, then press
#, and then press 3113899998888# , press the * then press # to exit configuration mode.
Method 3: using SMS
On your mobile phone, compose a SMS message as 12343113899998888# and send to your alarm panel.
Remark: The status LED is lit on the panel to indicate at the configuration mode, the status light is off upon exit.