EN
::: 38
Set integarted alarming
enable or disable the integrated alarm upon alarm. 1 is enabled and 0 is
disabled, the system default is 1.
example: users need to set the integrated alarming off,
Method one:
# , and then press 200# , press the * then press # exit Setup
Method two:
after calling and connected to the panel from remote, press 200#
Method three:
Send SMS message 1234200#
【
20
】
+
【
0/1
】
+
【
#
】
Enable or disable the GSM
Module
Used to set the GSM Module on and off, 1 is on, 0 is off, the system default is on.
example: the user needs to set gSM Module to off, so only use landline for
dialing.
Method one:
# , and then press 210# , press * then press # exit Setup
Method.two:
after calling and connected to the panel from remote, press 210#
Method three:
Send SMS message 1234210#
【
21
】
+
【
0/1
】
+
【
#
】
Restore factory setting
System restore factory setting
Method one:
# , and then press 9898#
Method two:
After calling and connected to the panel from remote, press 9898#
Method three:
Send SMS message 12349898#
remark:
this feature will restore all settings to factory default apart from the
configuration of sensors and remote control.
Syntax:
【
9898
】
+
【
#
】
Total System Rese
t
disconnect power to the alarm panel, turned off the battery switch alarm
panel, then press and hold the alarm panel of arM button while power-on. the
system will respond with short “beep” slowly for 5 seconds, then can release
ARM button. The system is now totally reset. All configuration has been cleared,
all sensors and remote controlled are deleted and password is restored to
original 1234.
Syntax:
Press and hold the ARM
button on the keyboard and
power on.
Note: Other than the SMS commands for assigning specific phone number for certain zone, alarm panel will respond
to all other SMS commands by replying confirmation of setting by SMS.
4.2 Commands of System Enquiries
press
button on panel to enter the query mode, alarm panel status led is blinking. then put in commands
as detailed in table below, when finished, Press *, and then press #, to exit the query mode.
note: in case keyboard password protection is enabled, please enter tne password to unlock before
other commands.
Query for voice alarm phone
number
To query the alarm panel currently saved to the first set to the Nineth group
voice alarm phone number.
press alarm panel query key of your keyboard, then blinking status led on the
panel, and then press 31#, the alarm panel lcd show 13812345678 means
alarm panel’s first set of alarm numbers are 13812345678
Syntax:
3
+
【