38
EN
Conduct the following operations at least every 6 months. If in high intensity of use,
shorten the period in between.
Disconnect the power supply:
(1) Clean and lubricate the screws, the pins, and the hinge with grease.
(2) Check the fastening points are properly tightened.
(3) Make the wire connection are in good condition.
Connect the power supply:
(1) Check the power adjustments.
(2) Check the function of the manual release.
(3) Check the function of photocells or other safety device.
F- MAINTENANCE
Problem
Solutions
Overheated Back-up Batteries
Check the wiring connection of the batteries.
The gate doesn’t move when
pressing the button of the
transmitter
1. Check if the power is higher than 22v
2. Ensure you all the wirings are well connected on the terminal block
3. Ensure you the good condition of the fuse or circuit breaker of your
supply
The gate opens but doesn’t close
Check if the LED1 indication is turned on in which case check the
photocells, their connections and their alignings. Put the program H-0
for the photocells to be inactive during the check of your connections.
The gate doesn’t open entirely
Increase the power with the program 7 (setting from 7-1 to 7-6). Update
the phases of slowdown with the program 6 (settings from 6-1 to 6-4).
However on windy day, stops can be contasted since the automation
kit is subjected to anti-pinch and crushing safety norms (but it’s not a
defect of the device)
The photocells don’t work
Check the photocells are activated with the H : H1 program. Check the
red LED of the RX photocell is not turned. If it is the case, there is a
aligning defect of your photocells.
The remote control don’t have a
good sensing range
Check your batteries power. Check the antenna connection and that the
single wire doesn’t touch the braid.
G- TECHNICAL ASSISTANCE
G1- Troubleshooting
If the diagnostic or maintenance process doesn’t settle the breakdown, thanks to contact our technical center
and hotline.
H- WARRANTY
Keep the bar code and your proof of purchase carefully. We’ll ask you it to activate the warranty.
The invoice will be required as proof of purchase date.
Are never covered by our warranty:
• Damage resulting from the consequences of a bad installation (bad wiring, reverse polarity ...).
• Damage resulting from improper use of the device (use in contradiction with the manual) or its modification.
• Damage resulting from the consequences of the use of components not from SCS SENTINEL.
• Damage due to lack of maintenance, physical shock.
• Damage due to weather: hail, lightning, strong wind etc..
• Returns made without a copy of the invoice or receipt.