background image

Documentazione

Tecnica

M90

rev.  

0.1

02/2002

©

 CAME

CANCELLI

AUTOMATICI

MR8106

CANCELLI AUTOMATICI

119PM90_GB

AUTOMATIC

 

DOORS

MICROWAVE

 

RADAR

 - 

UNIDIRECTIONAL

ENGLISH

TECHNICAL
SPECIFICATIONS

Technology 

: hyperfrequency and 

microprocessor

Frequency emitted 

: 24.125 GHz

Power density emitted

: << 5 mW/cm

2

Mounting height 

: 4 m max

Tilt angle 

: 0° to 90° vertical
: –30° to +30° lateral

Detection area (typical)

• wide sensing field

: 4 m (W) x 2 m (D)

• narrow sensing field  : 2 m (W) x 2.5 m (D)

Detection mode

: motion

Minimum speed

: 5 cm/s (measured in axis 

of radar)

Supply voltage 

: 12 to 24 V AC ±10%
: 12 to 24 V DC +30 %/–10 %

Mains frequency 

: 50 to 60 Hz

Power consumption 

: <  2 W

Standard output relay (free potential contact)

• Max contact voltage  : 75 V DC / 50 V AC
• Max contact current

: 1 A (resistive)

• Max switching power : 30 W (DC) / 60 VA (AC)

Output hold time 

: 0.5 s to 9 s (adjustable)

Manual adjustments

• sensitivity (by push buttons)
• orientation of sensing field (mechanically)
• shape of sensing field (choice of antenna)

Remote control adjustment

• sensitivity
• hold time
• multiple functions

Temperature range

: from –20°C to +55°C

Immunity

: electromagnetic compatibility 

(EMC) in accordance with 
89/336/EEC

Dimensions 

: 120 mm (W) x 80 mm (H) x 

50 mm (D)

Weight

: 0.215 kg

Material

: ABS

Colour of housing 

: anthracite grey, aluminium finish 

or white

Length of cable 

: 2.5 m

DESCRIPTION 
OF
THE SENSOR

Narrow sensing field antenna

Terminal block

Push b/–

Led

Adjustment for 

vertical position  

of antenna

Adjustment of

lateral position of

antenna

Planar antenna

wide original sensing field

Cover viewed 

from inside

INTERNAL VIEW

INSTALLATION
TIPS

• The sensor must be firmly 

fastened in order not to 
vibrate

• The sensor must not have 

any object likely to move 
or vibrate in its sensing 
field

• No fluorescent lighting in 

the sensing field

• The sensor must not be 

placed directly behind a 
panel or any kind of 
material

Содержание MR8106

Страница 1: ...adjustable Manual adjustments sensitivity by push buttons orientation of sensing field mechanically shape of sensing field choice of antenna Remote control adjustment sensitivity hold time multiple fu...

Страница 2: ...the cable where it its supposed to go through Run the cable through the orifice designed for this purpose Position the sensor and tighten the two screws Make sure you leave enough cable to reach the...

Страница 3: ...protective cover of the antenna 3 elements antenna 6 elements antenna SENSING FIELDS ACCORDING TO THE TYPE OF ANTENNA TYPE The sensing fields here on the right correspond to the following adjustments...

Страница 4: ...al operator B THE POSITION OF THE SENSING FIELD IS DETERMINED BY THE VERTICAL TILT ANGLE OF THE ANTENNA To obtain a sensing field far from the door the tilt angle of the antenna must be set at the max...

Страница 5: ...pond to the following adjustments wide sensing field antenna lateral angle of antenna 30 30 sensitivity 1 6 9 Mounting height 2 2 m C THE LATERAL POSITION OF THE SENSING FIELD IN FRONT OF THE DOOR IS...

Страница 6: ...ll not open The sensor power is off a Check the supply The LED does not light up b Check the supply voltage The sensor does not respond to the The batteries have been inserted Check battery insertion...

Страница 7: ...Plus button 2 Unlock 3 Minus button 4 Hold time 5 Sensitivity 6 Detection mode 7 Immunity 8 Not used Not used Check values 9 Lock 10 Relay configuration 11 Not used Default value 12 Not used For opti...

Страница 8: ...pidly while the unit waits Use NUMBER buttons 1 3 1 to select the type of digital filter required for the corresponding numerical value button 1 detection of quasi presence It then continues to flash...

Отзывы: