35
EN
8
Open partially
(pedestrian
opening)
8-1
3 seconds
This function can adjust the time of
opening partially.
The factory setting is « 8-2 »
8-2
6 seconds
8-3
9 seconds
8-4
12 seconds
8-5
15 seconds
8-6
18 seconds
9
Pre-Flashing
9-0
The flashing light
blinks when the
gate starts to move
The factory setting is « 9-0 »
9-1
The flashing light
blinks 3 seconds
before the gate
starts to move
A
Over current
reverse setting
A-0
Stop
The factory setting is « A-3 » .
The reverse function only operates 3
times and then stops.
If gate reverses, the auto close
function will be cancelled.
A-1
Reverse 1 second
A-2
Reverse 3 seconds
A-3
Reverse to the end
C
Full open remote
switch
(on the remote
control)
C-1
The top left button
The factory setting is « C-1 » .
C-2
The top right button
C-3
The bottom left
button
C-4
The bottom right
button
E
Pedestrian open
remote switch
(on the remote
control)
E-0
No function in
transmitter
The factory setting is « E-2 »
E-1
The top left button
E-2
The top right button
E-3
The bottom left
button
E-3
The bottom right
button
F
External device
control function
key
F-0
No function in
transmitter
The factory setting is « F-3 »
F-1
The top left button
F-2
The top right button
F-3
The bottom left
button
F-4
The bottom right
button