F3 function settings (function 3-1) :
Gate’s position
The reaction of photocells when detecting obstacles
Closed
No effect
Open
Reloads automatic closing time
Stop during moving
Reloads automatic closing time
Closing
Open
Opening
No effect
Photocellule 1
H
Photocells 1
function
H-0
Stand-by
The factory setting is « H-0 »
H-1
Ready
J
Photocells 2
function
J-0
Stand-by
The factory setting is « J-0 »
J-1
Ready
L
Stop command
L-0
Close
The factory setting is « L-0 »
Exit 11 and 12
L-1
Open
P
Remote control
function
P-1
Close
The factory setting is « P-1 »
P-2
Open
Photocells
D3- Testing and checking
Make sure the general safety precaution «WARNING» has been carefully observed :
• Release the gearmotor with the proper release key.
• Make sure the gate can be moved manually during opening and closing phases with a force of max
390N (40 kg approx).
• Lock the gearmotor.
• Using the key selector switch, push button device or the radio transmitter, test the opening, closing and stopping
of the gate and make sure the gate is in the intended direction.
• Check the devices one by one (photocells, blinker, key selector, etc.) and confirm the control unit recognizes
each device.
D4- Recognition of LED
LED indications
Descriptions
LED 1 Photocells
The LED1 turns on, when there is an obstacle between the photocells or an aligning
defect or a connection defect (Be carefull, function H must be activated with a connected
photocell on PH1).
LED 2 Photocells
The LED2 turns on, when there is an obstacle between the photocells or an aligning
defect or a connection defect (Be carefull, function J must be activated with a connected
photocell on PH2).