SCP SCIENCE
38
KeyPad
Version 1.0
INSTALLATION
UNPACKING
Retain all packing material in case
you need to return the instrument
to the manufacturer for service.
1.
Verify that all components listed have been
included:
•
Digi
PREP
block
• Operation
manual
•
Digi
PROBE
dongle
•
Digi
TUBE
rack
•
Jr
: 1 rack
•
MS
: 2 racks
•
LS
: 3 racks
•
HP
: 0 racks
Optional items, such as glass, quartz,
calibrated or non-calibrated digestion
tubes may have been included in the
shipment. Carefully check the packing
list(s) and the contents of shipping
cartons to verify that all items
listed are included. Please notify
SCP
SCIENCE
or your local distributor of
any
discrepancies.
Inspect the products for any shipping damage.
If the instrument has been damaged in shipping,
contact the freight carrier to report damage and
to fi le a damage report. Also contact the
SCP
SCIENCE
service department to report damage
and to request service information (see page 88
for contact information).
If you fi nd evidence of damage, do
not attempt to operate the instrument.
SETTING UP
Place
the
Digi
PREP
block in a fume hood. The
controller must
not
be placed in the fume hood.
With the controller’s power switch in the “off”
position, do the following:
• Verify that the voltage selector at the back of the
Digi
PREP
block is properly set.(Typically 115 for
North America, and 230 for Europe.)
• Connect the block’s umbilical cable to the
controller.
Disconnecting or reconnecting the
umbilical cable while the controller is
turned on, especially while it is on the
RUN screen, will likely result in
permanent damage to the instrument.
• Connect the power cord to the back of the
controller
.
• Connect the
Digi
SET
(or
Digi
SET
dongle)
to the back of the controller.
• Connect
Digi
PROBE
(or
Digi
PROBE
dongle)
to the back of the block.
If you are not using the
Digi
PROBE
or
Digi
SET
, the dongles must be
connected; otherwise, an error message
may be displayed.
• Insert the glass well liner into the
Digi
PROBE
well.
(Small hole near right of block)
• If you are using
Digi
PROBE
, insert the
PROBE
into the well liner.
The system is now ready to be plugged in
and turned on. Please see your controller
manual for operation instructions.
NOTE
NOTE
NOTE
WARNING
WARNING
Содержание DigiPREP
Страница 61: ...KeyPad Version 1 0 SCP SCIENCE 61 ELECTRICAL SCHEMATIC DigiPREP HT ...
Страница 73: ...KeyPad Version 1 0 SCP SCIENCE 73 HEATER VERIFICATION ...
Страница 83: ...KeyPad Version 1 0 SCP SCIENCE 83 ...
Страница 84: ...SCP SCIENCE 84 KeyPad Version 1 0 ...
Страница 85: ...KeyPad Version 1 0 SCP SCIENCE 85 ...
Страница 86: ...SCP SCIENCE 86 KeyPad Version 1 0 NOTES ...
Страница 87: ...KeyPad Version 1 0 SCP SCIENCE 87 NOTES ...