EH222 E and Condensing Unit
Remote Low Side Cuber User Manual
June 2017
Page 4
Model
Electrical
volts/Hz/phase
Minimum
Circuit
Ampacity
Maximum
Fuse Size
System Charge,
oz of R-404A
Cabinet Size*
w” x d” x h”
Unit
Weight (lb)
EH222SL-1E
115/60/1
1.13
15
shipped w/none 22 x 16.5 x 29
~100
ECC0800-3E
208-230/60/3
10.6
15
192
32 x 39 x 39.75
~300
ECC1410-32E 208-230/60/1
15.8
30
248
32 x 39 x 39.75
~310
ECC1410-3E
208-230/60/3
11.6
20
248
32 x 39 x 39.75
~310
* See cabinet drawings for detailed dimensions.
Location Limitations
Maximum Distance between Head and Condensing
Unit: Limited to the length of the longest available
single tubing kit, 75 feet.
Maximum Condensing Unit Elevation over Ice Making
Head: 35 feet.
Note: Elevations greater than 20 feet require
installation of a suction line trap at the 20 foot mark.
Maximum Ice Making Head Elevation over
Condensing Unit: 15 feet.
Line Routing:
• Allowed: One rise after a drop.
• Allowed: One drop after a rise.
• Not Allowed: More than one rise after a drop
• Not Allowed: More than one drop after a rise.
Model Number Locations
Ice Making Head
The dataplate on the back of the ice machine contains
the model number, serial number and electrical data.
A second plate, located behind the front panel at
the lower right front, also lists the model and serial
numbers.
Condensing unit
The dataplate on the end contains the model number,
serial number, electrical data and system refrigerant
charge.
A second plate, located behind the side panel on the
deck, also lists the model number, serial number and
refrigerant charge.
Specifications and Location Information