EH222 E and Condensing Unit
Remote Low Side Cuber User Manual
June 2017
Page 14
Water Supply:
A 3/8" flare nut on tubing is located at the top panel,
near the refrigeration tubing.
Inside the hardware bag, inside the cabinet, a
3/8" inch double male flare adapter (flare union) is
supplied. Use the supplied adapter to make a 3/8"
male flare fitting for the water inlet.
Connect a cold, potable water supply to the 3/8” water
inlet fitting installed above. Use 3/8" OD copper or
other comparable sized tubing for the water supply.
Note: This is an NSF listed ice machine and contains
provisions for back-flow prevention in its design. No
external back flow preventer is required.
Water Supply Connection
Communication Cable
Suction Line Insulation