Page 11
Page 11
MIN.
10
°
C
5
°
C
1 bar
-10%
Important operating requirements:
Air temperature
Water temperature
Water pressure
Electr. voltage variations
from voltage rating
specified
on nameplate
SPECIFICATIONS
ELECTRONIC CUBER MODEL AC 226
MAX.
40
°
C
35
°
C
5 bar
+10%
ice making capacity
AIR COOLED MODELS
WATER TEMPERATURE
AMBIENT
TEMPERA
TURE
ICE PR
ODUCED PER 24 HRS
.
WATER COOLED MODELS
148
144
140
136
132
128
124
120
116
112
108
104
100
96
92
88
84
Kg.
10
21
32
38
°
C
o
32
27
21
15
10
°
C
o
WATER TEMPERATURE
AMBIENT
TEMPERA
TURE
ICE PR
ODUCED PER 24 HRS
.
152
148
144
140
136
132
128
124
120
116
112
108
Kg.
10
21
32
38
°
C
o
32
27
21
15
10
°
C
o
NOTE
. The daily ice-making capacity is directly related to the condenser air inlet temperature, water
temperature conditions of the condenser air filter and age of the machine.
Production charts shown indicate the production of ACM models; ice production of ACL and ACS
models is 10% lower.
To keep your SCOTSMAN CUBER at peak performance levels, periodic maintenance checks must
be carried out as indicated on Maintenance and Cleaning section of this manual.