26
%0801.
Auto HDCP management, activate
carrier native mode
%0801
%9973.
Query the HDCP status of the inputs.
In
01 02 03 04
HDCP N Y N N In
05 06 07 08
HDCP N N N N
In
09 10 11 12
HDCP N N N N
In
13 14 15 16
HDCP N N Y Y
%9974.
Query the HDCP status of the outputs.
Out 01 02 03 04
HDCP N N N N Out
05 06 07 08
HDCP N N N N Out
09 10 11 12
HDCP N N N N Out
13 14 15 16
HDCP N N N N
%9978.
Query the HDCP compliant status of
the inputs.
In
01 02 03 04
HDCPEN Y Y Y Y
In
05 06 07 08
HDCPEN Y Y Y Y
In
09 10 11 12
HDCPEN Y Y Y Y
In
13 14 15 16
HDCPEN Y Y Y Y
7.5.6 EDID Management
Command
Function
Feedback
Example
EDIDPCM[x].
Set the audio part of input port [x] to PCM
format in EDID database.
EDIDPCM[x]
EDIDG[x].
Get EDID data from output [x] and display
the output port number.
Hexadecimal EDID
data and carriage
return character
EDIDMInit.
Restore the factory default EDID data of
every input.
EDIDMInit.
EDIDM[X]B[Y].
Manually EDID switching. Enable input[Y]
to learn the EDID data of output[X]. If the
EDID data is not available, then set it as
initialized EDID data.
EDIDM[X]B[Y]