22
Please set the parameters of COM number, baud rate, data bit, stop bit and the parity bit
correctly, only then will you be able to send command in Command Sending Area.
7.5 RS232 Command
NOTE
:
§
Case-sensitive.
§
Please disconnect all the twisted pairs before sending command EDIDUpgrade[X].
§
In the commands, “[”and “]” are symbols for easy reading and do not need to be
typed in actual operation.
§
End the commands with the ending symbols “.” and “;”.
Baud rate: 9600
Data bit: 8
Stop bit: 1
Parity bit: none
7.5.1 System Configuration
Command
Function
Feedback Example
/*Type;
Inquire the models information.
SC38.MX16
/^Version;
Inquire the version of firmware
VX.X.X
%9964.
Query the IP address.
IP:XXX.XXX.X.XXX
%0911.
Reset to factory default.
Factory Default
Undo.
To cancel the current operation.
Undo Ok!
Out 01 02 03 04
In
01 01 01 01
PWON.
Work in normal mode.
PWON
PWOFF.
Enter into standby mode and cut off the
power supply to MHUB Receivers.
PWOFF
STANDBY.
Enter into standby mode. (Do not cut off
the power supply to HDBaseT
Receivers, press other buttons or send
other commands to start.)
STANDBY
%9962.
Query the power status
STANDBY/PWOFF/
PWON
Firmware[x].
X=01, update the input card firmware.
X=02, update the output card firmware
(9~16).
X=03, update the output card firmware
(1~8).
Firmware 04
SC38.MX16
Scion Tech
User Manual
Tel: +44 (0) 1635 862484
www.scion-tech.co.uk