Operation
Operation Manual - All
S
P Rock Valve Model
s
76
revD
a
te
S
etting the
S
tabilizer
s
•
Position the dunnage pads (use scrap plywood,
2x4’s, etc.) on the ground where the stabilizer
will be positioned after extension.
•
Drop each stabilizer to its pad and insert the
locking pin. Jack the front of the unit using the
tongue jack until the weight of the unit is on
both stabilizers.
•
If the unit has hydraulic stabilizers, you must
be sure the faucet valves (Figure 22) are open
to supply hydraulic fluid to the system and
activate the stabilizer hand valves to the extend
position until the unit is supported properly.
Generally, that means each stabilizer must
begin to feel the weight of the unit. Then close
the valves.
Operating the Pump
•
Connect the remote control cable or dummy
plug into the control panel.
NOTE!
The
pu
m
p
will not f
u
nction witho
u
t one of
these
p
l
ugg
e
d
in.
•
Turn the Pump Switches to the OFF position.
•
Place Pump shift lever into the NEUTRAL
position.
•
Make sure all Emergency Switches are in the
RUN positions.
•
If using the optional radio (cordless) remote,
Engine won't start unless radio remote and
receiver are linked. Turn the radio on by using
the following sequence:
1. Turn the ignition key to the
ON
position
which supplies power to the receiver.
2. Engage the E-stop on the radio remote.
3. Press power button on radio remote, light
will flash.
4. Disengage E-stop on radio remote, light
will be solid.
•
Wait 10 seconds before turning ignition key to
engage the starter.
•
For cold weather starts use the following
procedure:
a. Move the throttle lever to the low idle position
before you start the engine.
NOTE!
If necess
a
ry, incre
a
se the throttle sli
g
htly so
the en
g
ine will st
a
rt in col
d
con
d
itions. The
en
g
ine sho
u
l
d
not excee
d
1500
R
PM
u
ntil
the oil
p
ress
u
re h
a
s incre
a
se
d
.
b. Turn the engine start switch two clicks, which
should illuminate the glow plug lamp, and hold
in that position for at least 6 seconds. This will
activate the glow plug and aid in the starting of
the engine.
NOTE!
Do not o
p
er
a
te the
g
low
p
l
ug
s for more th
a
n
30 secon
d
s
a
t
a
time. D
a
m
ag
e to the
g
low
p
l
ug
s co
u
l
d
occ
u
r.
c. After 6 to 10 seconds, turn the engine start
switch to the START position and crank the
engine.
Outrigger faucet valves
500
HydO
utrigger
.eps
Outrigger activation
handles
Figure 22
Optional hydraulic outrigger
control
s
s
hown here on the
S
P
500
NOTE!
W
hen
u
nit is st
a
bilize
d
a
n
d
le
v
el the wheels
sho
u
l
d
rem
a
in in cont
a
ct
with the
g
ro
u
n
d
to lessen
a
ny
p
ossible mo
v
ement of
the m
a
chine while
pu
m
p
in
g
Home
TOC
TOC
Содержание 30100750
Страница 8: ...Table of Contents Operation Manual All SP Rock Valve models viii revDate Home TOC TOC Print Print ...
Страница 14: ...Introduction Operation Manual All SP Rock Valve Models 12 revDate NOTES Home TOC TOC Print Print ...
Страница 70: ...Overview Operation Manual All SP Rock Valve Models 68 revDate NOTES Home TOC TOC Print Print ...
Страница 100: ...Operation Operation Manual All SP Rock Valve Models 98 revDate NOTES Home TOC TOC Print Print ...
Страница 126: ...Maintenance Operation Manual All SP Rock Valve Models 124 revDate NOTES Home TOC TOC Print Print ...
Страница 159: ...Alphabetical Index Operation Manual Line pumps ALPHABETICAL INDEX swg99a001 eps Home TOC TOC Print Print ...
Страница 164: ...Alphabetical Index Operation Manual All SP Rock Valve Models 162 revDate Home TOC TOC Print Print ...