Preparation
•
The Fan must be installed with the proper blades to match the fan assembly that are marked to
indicate their suitability with this model.
•
No other blades can be substituted.
•
Check to see if you have all the tools required for the installation.
•
Verify that all fan components were received.
•
Check drawings and layouts provided to locate where the Fan is to be installed.
•
Ensure work area is safe and that all security, policies and procedures for the facility are met.
•
Inspect the lift device or mobile platform.
•
Each person installing the Fan must use a safety harness at all times.
•
Other safety requirements may be required for installation.
•
All workspace safety requirements, lock out procedures and hoarding of construction zone for the
assembly and installation must be met and followed.
•
This appliance is not intended for use by persons [including children] with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they have been
supervised or instruction concerning use of the appliance by a person responsible for their safety.
•
Children should be supervised to ensure that they do not play with the appliance.
•
The mounting of the suspension system shall be performed by a certified contractor or suitably
qualified persons.
•
DO NOT LIFT, CARRY OR HANG FAN BY POWER CABLE. This could possibly cause the safety
disconnect system to disconnect power to the fan.
Clearances
•
Open ceiling, center of fan to roof deck for ideal operating performance without compromising
overall fan performance
•
Min 12” [304.8 mm] from fan blade’s leading edge to obstruction above or below fan.
•
Min 8” [203 mm] from side of fan to any obstruction
•
Min floor to fan leading edge height 120” [3050 mm]
Contractor is responsible for verifying all site conditions to include field dimensions where applicable.
If the contractor elects to make any changes without notifying Schwank Ltd. the contractor is
responsible for the same. All drawings are to be used as general architectural intent unless otherwise
stamped. See Engineer drawings for structural design information. Contractor to ensure that all
building departments and authorities are informed in regard to the work and that all permits are
attained before commencing work.
Installation Preparation
Warning!
To reduce the risk of fire, electric shock, or injury
to persons, observe the following:
Safety