18
19
schwankgroup.com/monsterfans
schwankgroup.com/monsterfans
Input:
120/240V 2.9/1.45A 1 PH
50/60Hz
LED:
25W
Electrical Installation
HMI Control
HMI/CAT 5 Cable Connection
75ft of Cat 5 cable is supplied to connect the HMI to the fan. This is a simple “plug and play”
application once the cable is ran. Level and install HMI within reach of the 75ft CAT 5 cable using
supplied fasteners. It is recommended the fan remain in line of site of the HMI.
HMI Control
The bottom left button toggles ‘Light’ to ‘Fan’ depending on what functionality you are looking to set
or adjust. When the screen says ‘Fan’, the remaining buttons on the keypad are controlling just the
fan. When the screen says ‘Light’, the remaining buttons on the keypad are controlling just the light.
The centre button is the on/off control. This button controls both the fan & light, however; they are
controlled separately depending on which functionality the interface is showing.
The top left button only works when the interface is controlling the ‘Fan’. This button is for forward and
reverse functionality of the fan as indicated by the left and right arrows.
The up and down buttons on the right of the control adjust the speed of the fan or the brightness of
the light depending on which functionality the interface is showing. The value is displayed 0%-100%
and is adjusted in increments if 5%. 100% displayed for the fan is equivalent to full speed and 100%
displayed for the light is full brightness. The control will remember the last speed & light values and will
automatically resume those settings once the fan is turned back on.
Note:
The Fan System is designed to monitor motor and controller temperatures and in the event
that operating temperatures exceed control limits, fan speed will reduce until the system is within
temperature limits. No user intervention is needed.