32
schwa-medico
Operating Manual - PhalliMax
When you press the
-button, instead of the number of the therapy day and the
therapy session, the average intensity will be displayed that was used for stimula-
tion during the respective session. You will see the intensity for channel 1 on the
left side, and the intensity for channel 2 will be displayed on the right.
Note:
The therapy days in the therapy memory refer to the days on which stimula-
tion took place using the PhalliMax. They have nothing to do with the calendar
date and do not account for any of the days on which the PhalliMax was not used.
For example: The first therapy was performed on Monday, the second on Tuesday,
and the third on Friday. In this case Monday is therapy day 1, Tuesday is therapy
day 2, Tuesday, and Friday is therapy day 3.
Holding down the
-button for 3 seconds deletes the therapy memory. In that
event the display will show “Clr” for two seconds. You will then automatically leave
the therapy memory display.
3.12 Turning off the device
While stimulation is off, press the
-button to turn off the PhalliMax. If the charge
on the battery is no longer sufficient, or if the device is not operated for more than
2 minutes without running stimulation, it will turn off automatically.
4 Electrodes
You can use the PhalliMax either with self-adhesive electrodes or with a loop elec-
trode and a self-adhesive electrode. The following instructions are intended to
help you use the electrodes correctly.
4.1 Self-adhesive electrodes
Self-adhesive electrodes are reusable. To increase their service life, please note the
following recommendations:
»
Clean your skin with water and soap before attaching the electrodes. It should
be dry and as free of oil as possible.
»
Do not use ointments, creams, etc. before attaching the electrodes
»
Do not affix the electrodes to damaged or diseased areas of skin.