![SCHUNK SRU-plus20-60 Скачать руководство пользователя страница 71](http://html.mh-extra.com/html/schunk/sru-plus20-60/sru-plus20-60_assembly-and-operating-manual_1216060071.webp)
Maintenance
12. Tighten screw (3) and then loosen approx. 1/4 revolution.
13. Swivel repeatedly to test the setting, if necessary set again
Electrical circuit diagram with two 5/3 directional control
valves (example) [
8.7 Disassembly and assembly
8.7.1 Dismantling and assembling rotary actuator (base unit)
1. Ventilate rotary actuator.
2. Remove all air connections,
3. Dismantle sensors if necessary.
4. Unscrew screws (8),(9) and remove clamp shell (10), then
remove both stop covers (7).
5. Remove curved cover (3).
6. Mark the installation position of the pinion (1) and the
pistons (4).
7. Unscrew protective cover (5).
8. Remove safety ring (6) on pinion (1).
9. Take pinion (1) out of the housing (2).
10. Take both pistons (4) out of the housing (2).
11. Assemble rotary actuator in the reverse order.
✓
Unless otherwise specified, secure all screws and nuts with
Loctite no. 243 and tighten with the appropriate tightening
torque.
71