![SCHUNK SRU-plus20-60 Скачать руководство пользователя страница 44](http://html.mh-extra.com/html/schunk/sru-plus20-60/sru-plus20-60_assembly-and-operating-manual_1216060044.webp)
Assembly
44
11.00 | SRU-plus 20 - 60 | Assembly and Operating Manual | en | 389443
5.4.5 Set locked center position
Depending on the start-up direction of stop
A
(11) or stop
B
(10),
the center positions can be set the same or differently.
1. Ventilate rotary actuator.
2. Loosen screw (1) by approx. one revolution.
3. Actuate air connection
B
(2).
✓
Rotary actuator swivels to stop
A
(11).
4. Ventilate air connection
B
(2) and actuate air connection
C
(5).
✓
Stop
C
(3) locks.
5. Actuate air connection
A
(4).
✓
Rotary actuator swivels to stop
C
(3), basic setting 90°.
6. Turn stop
C
(3) to the required center position.
7. Ventilate air connection
C
(5).
✓
Rotary actuator swivels to stop
B
(10).
8. Ventilate air connection
A
(4) and actuate air connection
D
(7).
✓
Stop
D
(8) locks.
9. Actuate air connection
B
(2).
✓
Rotary actuator swivels to stop
D
(8).
10. Turn stop
D
(8) to the required center position.
11. Tighten screw (1).
✓
Tightening torque: 20-40: 10 Nm / 50-60: 24 Nm
12. Swivel repeatedly to test the setting, set again if
necessary,
.