![SCHUNK SRU-plus20-60 Скачать руководство пользователя страница 47](http://html.mh-extra.com/html/schunk/sru-plus20-60/sru-plus20-60_assembly-and-operating-manual_1216060047.webp)
Assembly
1. Connect magnetic switch and secure cable, see sensor
assembly and operating manual.
2. Actuate air connection
A
(4).
✓
Pinion (2) swivels towards the end position.
3. Slide the first magnetic switch (6) into a groove (5).
Or:
Screw magnetic switch (6) into a groove (5) (1).
4. Slide magnetic switch (6) until it switches and the LED (7)
illuminates.
5. Tighten set screw (8).
✓
Tightening torque: 10 Nm
6. Ventilate air connection
A
(4).
7. Actuate air connection
B
(3).
✓
Pinion (2) swivels into the other end position.
8. Slide the second magnetic switch (6) into the other groove (5).
Or:
Screw magnetic switch (6) into the other groove (5) (1).
9. Slide magnetic switch (6) until it switches and the LED (7)
illuminates.
10. Tighten set screw (8).
✓
Tightening torque: 10 Nm
11. Check switching positions, set again if necessary.
Center position
variant
Rotate unit in the center position and mount sensor analogously.
47
11.00 | SRU-plus 20 - 60 | Assembly and Operating Manual | en | 389443