Assembly and settings
04.00 | RST-D | Assembly and Operating Manual | en | 389517
25
Load swivels in the
clockwise / anti-
clockwise direction
■
The load occurring during operation is mounted onto the
product.
Ø
Unscrew counter sleeve (09).
Ø
Undo the screws (62) until the damper can be turned slightly.
✓
If the screws (62) have come loose, compressed air can
escape to a small extent.
Ø
Adjust the dampers (57) to the swivel load by rotating back in
the area "a min." to "a max." or "b min." to "b max.". For
permitted adjustment dimensions, see following tables.
Ø
Tighten screws (62).
Ø
Test dampening during operation, correct swiveling time if
necessary, and readjust the setting of the dampers.
Ø
Tighten counter sleeve (09) as far as it will go.
✓
The damper is set correctly if the device reaches its end
position swiftly and without any mechanical impact.
Ø
Check whether the sequence and mechanical locking and
unlocking function without any problems. If necessary, correct
the setting.
Ø
NOTICE! The counter sleeve (09) is used for locking the damper
in place securely.
Make sure that the counter sleeve (09) is
mounted on both sides and is tightened as far as it will go.
Setting return stroke
If the load is only ever swiveled in one direction, the
corresponding second absorber must be reset to dimension "a
max." or "b max." to achieve fast cycle times (return stroke).
■
The damper is set in load-swivel direction.
Ø
Unscrew counter sleeve (09).
✓
The damper is set correctly if the product reaches its end
position swiftly and without any mechanical impact.
Ø
Undo the screws (62) until the damper can be turned slightly.
✓
If the screws (62) have come loose, compressed air can
escape to a small extent.
Ø
Rotate the dampers (57) back to "a max." or "b max." (see
following tables).
Ø
Tighten screws (62).
Ø
Tighten counter sleeve (09) as far as it will go.
Ø
Completely open connection throttle.