Troubleshooting
04.00 | RST-D | Assembly and Operating Manual | en | 389517
37
7.5 Useful load swings to end position
Possible cause
Corrective action
Swiveling speed too high.
Check swiveling time and adjust with
exhaust air throttles as necessary.
Shock absorber not well adjusted
Readjust absorbers.
Setting the end position dampers
Unfavorable installation.
Check construction.
RST-Dtype is undersized
Use RST-Dtype
7.6 Cycle times are not reached
Possible cause
Corrective action
ACTUAL operating pressure does not equal
the TARGET rated operating pressure
Check operating pressure.
Compressed air lines are not installed
optimally.
Check compressed air lines.
Use exhaust air throttles from the accessory
pack
Inner diameters of compressed air lines are
of sufficient size in relation to compressed
air consumption.
Keep compressed air lines between the
product and directional control valve as
short as possible.
Flow rate of valve is sufficiently large
relative to the compressed air consumption.
Dampening and return stroke not
completely reset (not for swiveling load in
both directions).
Readjust absorbers.
Setting the end position dampers
Damping wrong adjustet.
Readjust absorbers.
Setting the end position dampers
Swiveling speed not ideally set
Adjust swiveling speed.
Caution: Observe setpoint times.