Assembly
16
03.00 | RSS R1/W1 | Assembly and Operating Manual | en | 0889125
4 Assembly
4.1 Mount and connect receiver RSS R1
Ø
Secure the receiver in a control cabinet less than 10 m away
from the transmitter by fastening on a DIN rail (EN50022).
Ø
Wiring receiver:
Antenna socket X1:
- SMA socket for external antenna (SCHUNK recommends the
antenna RSS-R-A with ID no. 0377730)
Plug connector X2:
- X2.1 FE functional ground
- X2.2 + supply DC24V +external
- X2.3 - supply DC24V -external
Plug connector X3:
- X3.1 WD watchdog output, high signal if radio OK
- X3.2 LC limit value output, high signal, if battery OK, i.e. has
more than two weeks residual capacity.
- X3.3 DO1 output 1, if DIP 6 = DO2 inverted.
- X3.4 DO2 output 2, sensor signal 2, high, if clamping pressure
is not sufficient.
- X3.5 GND absolute dimension for the outputs.
NOTE
For safety reasons, the spindle must be stopped if the clamping
stroke pressure is not sufficient (D02=High), or the transmission
path is disrupted (WD=Low).
Plug connector: WAGO MULTI CONNECTION SYSTEM Series 722
Ø
Secure the repeater (2) and antenna (3) using the magnetic
base in the interior of the machine. For an example of the ar-
rangement, see the following illustration.