Assembly
36
01.00|ROTA THW vario |en-US
Changing the segmented clamping sleeve
Unscrew and remove the clamping bolts with the help of a
hexagon socket wrench. Remove the attached segmented
clamping sleeve and attach a new one. Make sure that the ejector
unit engages in the grooves of the ejector ring. In the case of
ejector rings with rotary drive, care must be taken to ensure that
the drivers engage in the segmented clamping sleeve. Use the
hexagon socket wrench to screw the clamping bolt back in until it
reaches the block. The following torque must be observed here:
Mandrel
size
Clamping bolt thread
Recommended tightening torque
0
M7 x 1
10 Nm
1
M9 x 1
20 Nm
2
M14 x 1
25 Nm
3
M25 x 1
55 Nm
Changing the stops
The stops are changed by loosening the 3 mounting screws.
Depending on the design, the clamping bolts (item 3) and the
segmented clamping sleeve (1) must be removed first.