Assembly and settings
5.4.11 Mounting analog MMS 22-A magnetic switch
CAUTION
Risk of damage to the sensor during assembly!
•
Observe the maximal tightening torque.
NOTE
If there is no T-nut available, slide the sensor according to
dimension I1 into the groove (2),
Sizes 40, 64, 80, 100, 125, 160, 200
1. Turn the sensor (1) into the groove (2).
OR: Slide the sensor (1) into the groove (2) until the sensor (1)
stops at the T-nut (3).
2. Secure the sensor (1) using the set-screw (4).
Tightening torque: 10 Ncm
3. Adjust sensor (1), see sensor assembly and operating manual.
Sizes 50, 200
During the monitoring, the first and last 15% of the nominal stroke
will not produce a change in the analog signal. It is therefore not
possible to monitor the end positions. If you have questions,
please contact SCHUNK.
Size
Stroke 1
Stroke 2
100%
15%
100%
15%
JGP-P 50
4 mm
0.6 mm
2 mm
0.3 mm
JGP-P 200
25 mm
3.75 mm
14 mm
2.1 mm